INSTALLATION INSTRUCTIONS

69-1043-2

TRADELINE®

T841A,B Easy-To-See™

 Heat Pump Thermostat

APPLICATION

The T841A, B Easy-to-See™ Heat Pump Thermostat 
provides 24 Vac control of 2-stage heating and 1-stage 
cooling in heat pump systems, using manual change-
over. 

The T841A Thermostat provides EM. HT.-HEAT-OFF-
COOL System switching and AUTO-ON Fan switching. 
The T841B Thermostat provides HEAT-OFF-COOL 
System switching and AUTO-ON Fan switching. 

The side of the thermostat features raised numbers for 
easy temperature setting by touch or sight. An audible 
click is heard with indents every two degrees as the 
temperature setpoint lever is moved. The thermostat 
wallplate features raised letters to aid in setting System 
switch and Fan switch settings. See Fig. 1.

The T841A,B includes a thermostat and wallplate.

Test holes are provided on the front of the thermostat to 
accommodate test meter probes without removing the 
thermostat from the wall. Remove the cover of the 
thermostat to expose the test holes that are labeled to 
correspond with the terminals on the thermostat back.

OPERATION

The stages of heat make sequentially as the temperature 
drops. Make refers to the mercury switch initiating a call 
for heat or cool.

There is about 1°F (0.6°C) between stages so the 
second stage (auxiliary heat) makes only when the first 
stage cannot handle the load. This °F is the interstage 
differential.

For T841A Thermostat only (not for T841B Thermostat): 
light emitting diode (LED) indicators light when 
something specific happens within the system:

When AUX. HT. green or amber LED lights, auxiliary 

heat (second stage heat) is operating because the 
weather is so cold, the heat pump alone cannot 
handle the load.

 When red EM. HT. LED lights, emergency heat is 

operating (electric strip heaters), because home-
owner physical y switched to EM. HT. position. See 
heating/cooling manufacturer instructions.

MERCURY NOTICE

This control contains mercury in a sealed tube. 
Do not place the control in the trash at the end of 
its useful life. If this control is replacing a control 
that contains mercury in a sealed tube, do not 
place your old control in the trash.

Contract your local waste management authority 
for instructions regarding recycling and the 
proper disposal of this control, or of an old control 
containing mercury in a sealed tube.

INSTALLATION

When Installing this Product...

1. Read these instructions carefully. Failure to follow 

them could damage the product or cause a hazard-
ous condition.

2. Check the ratings given in the instructions and on 

the product to make sure the product is suitable for 
your application.

3. Installer must be a trained, experienced technician.
4. After instal ation is complete, check out product 

operation as provided in these instructions.

CAUTION

Electrical Hazard.
Can cause Disconnect electrical shock or 
equipment damage.
Disconnect power before beginning installation.

IMPORTANT

— To prevent interference with the thermostat link-

age, keep wire length to a minimum and run 
wires as close as possible to the thermostat 
base.

— Do not short across coil terminals on the relay. 

This can burn out thermostat heat anticipator. 

— Never install more than one wire per terminal 

unless a factory-supplied jumper with a spade 
terminal is used.