Drawing for the instal ation of indoor and outdoor units

Necessary Tools for Instal ation

Driver

Torque wrench

(17mm,22mm,26mm)

Nipper

Reamer

Hacksaw

Pipe cutter

Gas leakage detector or

soap-and-water solution

Hole core dril

Flaring tool

Spanner(17,19 and 26mm)

Knife

Measuring tape

Indoor Unit

Place, robust not causing vibration, where the body can be supported sufficiently.

Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the

unit are not disturbed.

Place, possible to drain easily, where piping can be connected with the outdoor unit.

Place, where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around. (Refer to drawings).

Place where the distance of more than lm from televisions, radios, wireless apparatuses

and fluorescent lamps can be left.

In the case of fixing the remote control er on a wal , place where the indoor unit can

receive signals when the fluorescent

lamps in the room are lightened.

Outdoor Unit

Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are not increased.

Place, where discharged wind and noise do not cause a nuisance to the neighbors.

Place, where a distance marked

 is available as il ustrated in the above figure.

Before inserting power plug into receptacle, check the voltage without fail.

The power source is the same as the

corresponding name plate.

Instal an exclusive branch circuit of the power.

A receptacle shal be set up in a distance where the power cable can be

reached.Do not extend the cable by cutting it.

Power Source

Preparation

Read this manual before installation

Explain sufficiently the operating means to the user according to this manual
NO.0010506358

Installation Manual of Room Air Conditioner

F

A

C

E

D

Optional parts for piping

Non-adhesive tape
Adhesive tape
Saddle (L.S) with screws
Connecting electric cable

for indoor and outdoor

Drain hose

Heating insulating material

Piping hole cover

Floor fixing dimensions of the

outdoor unit (Unit:mm)

Fixing of outdoor unit

Fix the unit to concrete or block

with bolts (10mm) and nuts firmly
and horizontal y.
When fitting the unit to wal

surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of 
earthquake and strong wind.
If vibration may affect the

house, fix the unit by attaching a 
vibration-proof mat.

The marks from

to

in the figure are the

parts numbers.

The distance between

the indoor unit and the

floor should be more

than 2m.

The models adopt HFC free refrigerant R410A

more than

10cm

more than 5cm

more than 10cm

more than 10cm

more than10cm

more than15cm

more than 60cm

A

G

A

F

C

E

D

G

B

Arrangement of piping

directions

Rear left

Left

Rear

right

Right

Below

G

Please be subject to the actual product purchased , the above picture is just for your reference.

Attention must be paid to

the rising up of drain hose

113.5

583

113.5

5.

91

3

Selection of Installation Place