Installation Instructions 

RX11 LED Signal Round Modules 

200mm and 300mm 

 

 
 

 
 
 
 

 
Installation Steps: 

1.  Verify input voltage is within specified range on the back of the LED signal module before installation. 

Failure to do so wil  cause lamp to fail. 

2.  Open front cover of (customer supplied) traffic signal housing. 
3.  Remove outer lens and incandescent bulb from traffic signal housing OR existing LED signal module.  Retain 

all hardware as removed as it may be needed in subsequent steps. 
NOTE:  Installer is responsible for ensuring the disposal of removed components complies with all applicable 
regulatory requirements. 

4.  Ensure that a gasket is present around the perimeter of the new LED signal module. 
5.  Insert the LED signal module into the available cavity from previous LED module or incandescent bulb. 

NOTE:  Ensure that the arrow (

) on the back cover of the LED signal module is oriented pointing up. 

6.  Install mounting hardware to ensure that the LED signal module is securely fastened to traffic signal 

housing. 

7.  Connect the white wire to the neutral terminal block and the colored wire to the positive, supply voltage 

terminal block. 

NOTE:  Ensure that the correct wire is securely connected to correct terminal block for proper operation. 

8.  After installation of all modules is complete, ensure all traffic signal housings are closed and secured 

properly. 

9.  Apply power and ensure proper operation of traffic signal modules per intersection requirements as 

specified by customer. 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

…Page 2 

Voltage Rating 

Up arrow (

) 

 

 

Risk of Electric Shock 

Install unit in enclosure tested to 

be suitable for wet locations only. 

 

 

 

 

BEFORE YOU BEGIN 
Read these instructions completely and careful y. 

Prepare Electrical Wiring 

 

Electrical Requirements

  

  Do not use in wet locations 
  Fol ow al  National Electric Codes 

(NEC) and local codes. 

 

     

WARNING / AVERTISSEMENT

Risk of Electric Shock.  Disconnect Before Servicing or instal ing product.
Risque de choc électrique.  Couper l’alimentation avant le dépannage ou avant 
l’instal ation du produit.

 