GE PROFILE PD900DP User's Manual

GE welder User's Manual - PROFILE PD900DP.
Download
Page  of 2
4.7, 1584 votes
background image

For answers to your Monogram,® GE Profile™ or  

GE® appliance questions, visit our website at 

ge.com or call GE Answer Center® service,  

800.626.2000.

PD900DP 
GE Profile™ 30" Drop-In Electric Range

 

Note: Cabinets instal ed adjacent to slide-in ranges must have an 

adhesion spec of at least 194° temperature rating. 
Note: To reduce possibility of scorching the side wal s above the  

countertop when no load is present on burners, it is  recommended  

that a minimum of 6" spacing from adjacent side wall be allowed for 

possible extended, high-heat, element operation.
IMPORTANT: 30" DROP-IN RANGES ARE DESIGNED TO HANG 

FROM THE COUNTERTOP. IT DOES NOT REST ON THE FLOOR.  

FOR INSTALLATION ALTERNATIVES, REFER TO INSTALLATION 

INSTRUCTIONS PACKED WITH PRODUCT.

Optional Kits For Drop-In Electric Ranges (Available At Additional Cost)

Instal ation information: Before instal ing, consult instal ation 

instructions packed with product for current dimensional data. 

Accessory Backguards 

(Attaches to the back of range  

as a backguard when unit is instal ed  

in 30" free-standing cutout) 

JXS32SS (Stainless) - 4" High 

JXS32WW (White) - 4" High 

JXS32BB (Black) - 4" High 

JXS37WW (White) - 5-1/4" High 

JXS37CC (Bisque) - 5-1/4" High 

JXS37BB (Black) - 5-1/4" High
Rear Filler Strip 

WB07T10680 - Black Fil er Strip Assembly  

WB07T10681 - White Fil er Strip Assembly 

WB07T10682 - Bisque Fil er Strip Assembly

Specification Created 5/09

220804

Al  GE ranges are equipped with 

an Anti-Tip device. The instal ation 

of this device is an important, 

required step in the instal ation  

of the range.

Listed by 

Underwriters 

Laboratories

Dimensions and Instal ation Information (in inches) 

KW Rating

240V 11.6
208V 8.7

Breaker Size

240V 40 Amps
208V 40 Amps

Acceptable Electrical Outlet 

Area Also In Adjacent

Cabinet Or Under Floor

Conduit is 40" long

30" Min.

30" Min.

15" Min.

6" Min.  

from walls

7-1/2

2-7/8"

To Front Surface  

of Countertop 

30

36

27-1/2

25

23-3/16

If necessary,  

build upsides  

to 1-1/4" thick  

to provide  

countertop 

support

27

20-5/8" Door  

Clearance  

From Front  

Surface of  

Countertop

24

31-1/4

30

A/B*

Accessory 

Backguard

26-1/2**

*JXS37 is 5-1/4" and JXS32 is 4"  

(excluding handle)

**Total depth from wal  to 

front of closed oven door 

including handle is 29-1/2.

Acceptable Electrical Outlet 

Area Also In Adjacent

Cabinet Or Under Floor

Conduit is 40" long

30" Min.

30" Min.

15" Min.

6" Min.  

from walls

7-1/2

2-7/8"

To Front Surface  

of Countertop 

30

36

27-1/2

25

23-3/16

If necessary,  

build upsides  

to 1-1/4" thick  

to provide  

countertop 

support

27

20-5/8" Door  

Clearance  

From Front  

Surface of  

Countertop

24

31-1/4

30

A/B*

Accessory 

Backguard

26-1/2**

*JXS37 is 5-1/4" and JXS32 is 4"  

(excluding handle)

**Total depth from wal  to 

front of closed oven door 

including handle is 29-1/2.

0.643829s