GE Level Crossing Installation Guide

GE Transportation Installation Guide - Level Crossing.
Download
Page  of 2
4.8, 2054 votes
background image

 

  

 

 

Installation Instructions 

RG6 LED Signals – 12’’ (300mm) – Railway Grade Crossing 

 

  
 
 
 
 
 

 
Operating Specifications: 
 
Nominal Input Voltage:  

10V 

Voltage Range: 

8V to 16V AC 
8V to 20V DC 

Nominal Power Consumption: 

13.2 Watts 

 
 
  Always use a sun shielding apparatus such as a visor or hood over the signals.  
  Do not attempt to open the LED module. No assembly is required. 
 
Testing: 
 
When testing the lamp before installation, first check the electrical characteristics on the label on the back of the lamp 
(see box “B” below) to avoid damaging the lamp. 
 
Installation Steps

 
NOTE: Failure to properly follow these instructions may cause signal to malfunction. 
 
1.  Remove the incandescent bulb, reflector and lens assembly from the housing. 
2.  Feed wires of the LED signal module through the conduit in the housing. 
3.  Insert the LED signal into the lens slot and rotate it until the arrow on the back of the module (A) is aligned with the 

top of the housing. 

4.  Lock the LED signal module in place by tightening metal tabs over the rim of the module, or fastening a ring holder 

over the module, as applicable. 

5.  Connect the wires to the AAR terminals. 
 
 

 
 

 

…Page 2 

Visor / Hood 

 

 

 

BEFORE YOU BEGIN 
Read these instructions completely and careful y. 

Prepare Electrical Wiring 

 

Electrical Requirements 
  Do not use in wet locations 
  Fol ow al  National Electric Codes 

(NEC) and local codes. 

 

     

WARNING / AVERTISSEMENT

Risk of Electric Shock.  Disconnect Before Servicing or instal ing product.
Risque de choc électrique.  Couper l’alimentation avant le dépannage ou avant 
l’instal ation du produit.

 