GE H9 Luminaire Specification Sheet
HAZARDOUS LIGHTING
Guide Form Specifications – 2011
g GE
Lighting Solutions
GUIDE FORM SPECIFICATIONS
The complete luminaire designated _______ (identify) shal be a
GE POWR•GARD® luminaire, ordering number _______ (specify
H9, plus ordering number logic from catalog) UL844 Listed
for use in Class I, Division 1, Groups C and D (for paint spray
area fixture _______ [specify 50, 70 or 100] watt high pressure
sodium [HPS] or 100 watt mercury or metal halide, al voltages
with nameplate “Suitable for locations having deposits of
readily combustible paint residues.”), Class II, Division 1, Groups
E, F, and G locations or UL1598 Listed, Outdoor Salt Water
Marine(formerly UL595), or approved equal, for operation of one
_______ (specify [50, 70, 100, 150(55V), 200, 250 or 400] watt
high pressure sodium [HPS], [100, 175, 250 or 400] watt metal
halide or mercury) lamp from a nominal _______ (specify 120,
208, 240, 277 or 480) volt, 60 Hertz power source and shal be
capable of starting and operating the specified lamp within the
limits specified by the lamp manufacturer.
The luminaire shal contain a completely prewired integral bal-
last and optical assembly and be suitable for continuous ser-
vice, either indoors or outdoors, in an ambient temperature of
55°C for under 400 watts (40°C for 400 watt).
The luminaire shal have a clearly visible NEMA lamp identifica-
tion decal and a metal nameplate including pertinent luminaire
rating data. Labeling shal be in accordance with UL and NEMA
Listings. Standard construction is IP65.
POWR•GARD ® H9 LUMINAIRE
UL844, UL1598, OUTDOOR SALT WATER MARINE (OPTIONAL)
GENERAL DESCRIPTION
BALLAST OPERATION
The optical assembly shal contain a mogul base socket with
superior lamp gripping. The socket shal have the ability to
handle the higher pulse ratings of newer HID systems. The lu-
minaire shal contain an integral bal ast* that shal be prewired
to the lamp socket and terminal board (and ignitor for high
pressure sodium fixture). The bal ast shal be in ful compliance
with lamp-bal ast specifications available to the fixture manu-
facturer from the lamp manufacturers at the time of fixture
manufacture.
The bal ast shal reliably start and operate the lamp in ambient
temperatures down to -20°F for mercury and metal halide or
-40°F for HPS.
The luminaire and bal ast shal be from the same manufacture.
OPTICAL ASSEMBLY
The optical assembly shal include a _______ (specify
computer-designed high-impact resistant glass globe with or
without Maxi-Lux® guard, deep dome or angle dome reflector).
External reflectors shal be aluminum with a chemical y bonded
lightweight non-breakable ALGLAS® finish on inside and outside
surfaces for corrosion resistance.
The non-metal ic Maxi-Lux guard shal be of inverted design for
improved photometric performance.
MECHANICAL CONSTRUCTION
For ease of instal ation and to facilitate maintenance and re-
placement, the luminaire shal be supplied as components —
bal ast and optical, mounting, accessories.
The bal ast housing shal be of die-cast low-copper aluminum
al oy with an electrocoat gray paint finish.
The luminaire shal be _______ (specify pendant, flexible
pendant, wal , ceiling, angle stanchion or straight stanchion)
mounted. Al mounting adapters shal have Acme square-cut
threads (to reduce possibility of cross threading) and an elec-
tro-mechanical safety disconnect with an integral conduit seal
formed by the threaded male disconnect. Al external hardware
shal be stainless steel.
SUSPENDED VERSION
FLOODLIGHT VERSION
The floodlight version of this luminaire shal include a cable
connector with safety disconnect. The adjustable trunnion with
integral degree marker must be aimed below horizontal.
* REFER TO PRODUCT PAGE FOR BALLAST SELECTIONS. FOR
MORE DEFINITIVE INFORMATION, REFER TO BALLAST SPECIFICA-
TIONS IN TECHNICAL DATA SECTION.
YOU MUST USE TEMPERATURE PROFILE DATA TO PROPERLY SELECT LUMINAIRE
Related Manuals for GE H9 Luminaire
-
GE Hazardous Location H2 & H2U Luminaire Specification Sheet
2 pages
-
GE Hazardous Location MGA Specification Sheet
2 pages
-
GE Hazardous Location MGH & MGHU Specification Sheet
2 pages
-
GE Hazardous Location PMGA Specification Sheet
2 pages
-
GE Hazardous Location FP2 Specification Sheet
2 pages
-
GE Hazardous Location H4 T5 & T8 Fluorescent Luminaire Specification Sheet
2 pages
-
GE Hazardous Location P54H Specification Sheet
2 pages
-
GE Hazardous Location P54H Specification Sheet
2 pages