GE Zoneline® Deluxe Series Cooling and Electric Heat Unit

Specification Created 2/08

390577

For answers to your Monogram,® GE Profile™ or  

GE® appliance questions, visit our website at 

ge.com or cal  GE Answer Center® service,  

800.626.2000.

Electrical Wiring
Al  wiring, including instal ation of receptacle, must  

be made in accordance with local electrical codes  

and regulations.
Note: Aluminum wiring may pose special problems –  

consult a qualified electrician.
Gril e Options
Stamped Aluminum Gril e – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige) 

RAG63 (Bittersweet)

RAG62 (Maple) 

RAG67 (Extruded Aluminum)

Retrofit Kits:
RAK901L – Wal  Case Insulation for use with heat pumps. 

RAK40 – Deflector Kit to adapt chassis for use with  

existing exterior architectural louvered gril es.

Ducted Applications
2900 and 3900 series can be used with ductwork to heat or cool more than one room. RAK6052 

Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied 

to right or left of adaptor. Local y fabricated ductwork may be added to extend to maximum 

recommended distance of 15 feet.
Electrical Connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box 

and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers 

Design Data Manual for electrical connection information including use of sub-base for direct 

connected units. Instal ation must comply with local electrical codes and regulations.
Power Connection kits required on al  Zoneline chassis.

Wall Case Dimensions

RAB71 Wal  Sleeve

  Heavy-gauge galvanized steel, with insulation.  

  A  – 42",  B – 13-3/4",  C – 16"
RAB77 Wal  Sleeve

   Molded SMC fiberglass-reinforced polyester 

compound.  

A – 42-1/8",  B– 13-7/8",  C – 16-1/4

Wal  Opening Dimensions

  Add 1/4" to A and C dimensions for al  cut-out size. 

  RAB71 16-1/4" Min. H x 42-1/4" Min. W 

  RAB71 available in 16",  24",  28" and 31" depths 

  RAB77 16-1/2" Min. H x 42-3/8" Min. W

Maximum Cord Extension (in inches)

SIDE

VIEW

Inside

Room

  Cabinet

Outside

58

21

Grille

7-1/8

RAB71A = 16
RAB77A = 16-1/4

RAB71A = 20-7/8
RAB77A = 21

Room Air/Installation QSart

265 Volt Sub-Base Connected Units

Sub-Base

Power 

Connection Kit

Electric  

Heater Watts

Electric  

Heat Amps

Min. Circuit 

Protection 

(Amps)

RAK204E15

RAK5172

2,550

10.3

15

RAK204E20

RAK5202

3,450

13.7

20

RAK204E30

RAK5302

5,000

19.6

30

Dimensions and Instal ation Information (in inches) 

A

C

B

Zoneline RAC Wall Installation