GE BoxTimer 120V GE Time Switch 15600 Owner's Manual

GE Timers Owner's Manual - BoxTimer 120V GE Time Switch 15600.
Download
Page  of 1
4.2, 1197 votes
background image

We recommend that installation be made by a licensed electrician.

Disconnect power at main panel prior to installing or servicing this 

time switch or the equipment connected to it.

Connect in accordance with national and local electrical codes.

Supply Connections: Use gauge specified (AWG #8-14 ) suitable for 75ºC 

(167ºF).

Replace insulator before turning on electricity to unit.

INSTALLATION AND OPERATING INSTRUCTIONS TO SET ON AND 

OFF TIMES:  Light trippers turn ON. 

Dark trippers turn OFF. Place tripper on 

dial edge as shown in figure and set 

point of each tripper to desired oper-

ating time. Note if selected time is AM 

or PM. Hold tripper against dial edge 

and firmly tighten knurled screw.

120VAC/60Hz

O

F

F

O

N

TIM

E

ON TIME 

(Light Tripper)

MANUAL 

ON 

LEVER

MANUAL 

OFF 

LEVER

OFF TIME 

(Dark Tripper)

Knurled Screw

Dial Calibrations

HEAVY DUTY 

MECHANICAL 

TIME SWITCH

INSTALLATION AND OPERATING INSTRUCTIONS

TO SET DIAL TO TIME:

Turn dial counter-clockwise until correct time is indicated by 

arrow on nameplate.

FOR TEMPORARY MANUAL OVERRIDE:

Press down lever on right of nameplate to turn ON. Press down 

lever on left of nameplate to turn OFF. CAUTION: Do not rotate 

dial for manual override.

TO REMOVE MECHANISM FROM CASE:

Press lever near case latch to release mainplate and swing the 

movement out. To replace, insert mainplate projections in slots 

opposite latch and swing movement in until it latches.

15306

•  24 HOUR TIME SWITCH

SWITCH: 

SPST

CONTACT RATINGS: 

40 AMP 120-277VAC 

1000VA (120-277) PILOT DUTY

 

40 AMP TUNGSTEN 120VAC  120-277VAC SINGLE PHASE

 

20 AMP INDUCTIVE 

2HP 120VAC; 5HP 240VAC

TIMING MOTOR: 

120VAC 60Hz

POWER CONSUMPTION:  3 WATTS MAX

For seperate motor terminals, remove 
bridge from terminals L & 1

2

X

L

H

N

M

1

FOR 120 VAC

GE5360-41K2

469D

LOAD

Removable 

Bridge

15306 

MANUAL VERSION 1

12/15/09

WWW.JASCOPRODUCTS.COM