Frigidaire GLGQ2152EE User's Manual
137058000A 0808
Dryer Tech Data Sheet
This information is intended for Qualified Technicians Only.
CAUTION: DISCONNECT ELECTRICAL CURRENT BEFORE SERVICING
Please Return This Sheet to its Envelope in the Product for Future Reference
READING ERROR CODES
1. Non-Digital Readout Display Models: Rotate cycle selector knob to the 3 O’clock position.
Digital Readout Display Models: Rotate cycle selector knob clockwise (3) settings from the Normal cycle option.
2. Press and hold the Select and Pause Cancel buttons simultaneously for six seconds.
3. Immediately after, press and hold the START and Pause Cancel buttons simultaneously for 4 seconds.
4. Digital Readout Display Models: rotate the timer knob (1) click counterclockwise. The error code will appear in the digital
display.
Non-Digital Readout Display Models: rotate the cycle selector knob to the 2 O’clock position. The four indicator lights of
Drying, Cool Down, Wrinkle Rid (Press Saver), and Clean Lint Filter will flash the number of times for the first digit of
the code and the START indicator light will flash the number of times for the second digit. Take separate counts of each
indicator light, then repeat to confirm in order to be accurate in identifying the proper error code. The code is obtained by
counting the number of times the lights flash. Example E24: The four indicator lights would flash twice indicating the 2
and the START indicator light will flash four times indicating the 4. The four indicator lights and the START indicator light
start flashing at the same time. The control will pause for 2 seconds, then repeat the code.
NOTE: A letter appearing in the code stands for a number higher than nine. A = 10 B = 11 C = 12 D = 13 E = 14 F = 15
Example
Code
E4A: the first digit would be 4 and the second digit would be 10. If this code would appear on a washer in
the Non-Digital Readout Display Models, the four indicator lights would blink four times and the START indicator light
would blink ten times. Troubleshoot the problem by using the chart below.
To move on to the next code, press the OPTIONS button.
To clear code, press the Select button. Code will be cleared when mode is exited.
To exit this mode, simultaneously press and hold the Select and Pause Cancel buttons for six seconds.
Error Code
Label
Description
Solution
E10
General EEPROM
Fault
Problem with communication
between EEPROM and the
microprocessor.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
E11
Checksum Error
Problem with communications or
memory did not check, one has
become corrupted.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
E12
Non fatal R/W
error
Problem reading or writing to the
memory or input/output.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
E24
Control NTC Short
Circuit
Control thermistor or its wiring is
shorted.
Remove wires from control thermistor. Measure resistance of thermistor. If
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±
10%), check wiring between thermistor and electronic control. If good,
replace electronic control.
E25
Control NTC Open
Circuit
Control thermistor or its wiring is
open.
Remove wires from control thermistor. Measure resistance of thermistor. If
reading is not 50 K (± 10%), replace thermistor. If reading is within 50 K (±
10%), check wiring between thermistor and electronic control. If good,
replace electronic control.
E4A
Program Timeout
Fault
The drying time has exceeded
program time for that cycle.
Press Pause Cancel and SELECT buttons for 6 seconds to exit test modes.
Position cycle selector to NORMAL, temperature selector to HIGH HEAT
and touch START. Check for anything that would extend dry times such as:
no heat, restricted vent, blower fan blade broken or loose, dryer installed in
closet with solid door, or bad connection in moisture sensor bar circuit or
dirty bars. If dryer operates normally but code returns, replace electronic
control.
E5B
Heater Fault (no
heating)
Temperature reading of control
thermistor has not changed in a
certain amount of time.
Position cycle selector to NORMAL, temperature selector to HIGH HEAT
and touch START. Measure voltage across terminals on relay K2 (heater
relay) on electronic control. If meter reads 240V on electric models and
120V on gas models, replace electronic control. If meter reads zero, remove
power from dryer. Disconnect wire going to NO terminal on the relay K2.
Reconnect power and measure voltage drop between terminal COM on
relay K2 and neutral. If meter reads zero, wire between incoming line and
relay K2 is open. If meter reads 120V, check the rest of the heater circuit.
E68
Key (button) Struck
Fault
One of the keys (buttons) is stuck
closed (active).
Enter function test mode and perform key (button) test to determine which
button is at fault. Carefully free the and perform the test again. If button is
free but the key struck code still exists, replace electronic control.
E8C
Too many trips in a
period of time.
The safety (high limit) thermostat
has tripped too many times within
a certain period of program time.
Check for blocked lint filter, blocked exhaust, air leaks around air duct,
broken blower fan blades, worn or loose drum seals, dryer installed in closet
with solid doors or door seal not correctly seated.
EAF
Watch Dog Reset
Microcontroller has been reset by
internal Watchdog timer.
Clear code, exit mode and start dryer. If problem persists, replace electronic
control.
Related Manuals for Frigidaire GLGQ2152EE
-
Carrier Air Conditioners 24ABB3 Owner's Manual
2 pages
-
Vicks Air Conditioners V1200 Owner's Manual
2 pages
-
Trane Air Conditioners XL15i Owner's Manual
6 pages
-
Oreck Air Conditioners AIR12GU Owner's Manual
48 pages
-
Hunter Air Conditioners 30200 Owner's Manual
8 pages
-
Heat Controller Air Conditioners InverterFlex Series Owner's Manual
15 pages
-
Heat Controller Air Conditioners Patriot 80 Series Owner's Manual
4 pages
-
De'Longhi Air Conditioners PAC A110 Owner's Manual
18 pages
-
Trane Air Conditioners XE1000 Owner's Manual
6 pages
-
Mitsubishi Air Conditioners R410A User's Manual
18 pages
-
Sharp Air Conditioners CV10NH - 10,000 BTU Portable Air Conditioner Installation Manual
60 pages
-
White Rodgers Air Conditioners 1F78 User's Manual
6 pages
-
Goldstar Air Conditioners GWHD5000 Owner's Manual
44 pages
-
Duracraft Air Conditioners AMD-8500E User's Manual
8 pages
-
Trane Air Conditioners RTAC 140-400 User's Manual
252 pages
-
Haier Air Conditioners Commercial Cool CPN10XCJ User's Manual
36 pages
-
Haier Air Conditioners HSU-09HV03/R2(SDB) User's Manual
27 pages
-
Carrier Air Conditioners 30GB User's Manual
12 pages
-
De'Longhi Air Conditioners pinguino pac ct90 User's Manual
14 pages
-
Comfort-Aire Air Conditioners Air Conditioner PAD-121 User's Manual
19 pages
-
Kul Air Conditioners KU32085 User's Manual
28 pages
-
Trane Air Conditioners XR14 User's Manual
6 pages
-
Frigidaire Air Conditioners FFRH0822R1 Installation Instructions
6 pages
-
Arctic King Air Conditioners WINDOW/WALL TYPE ROOM AIR CONDITIONER User's Manual
20 pages