10

INSTALLATION REQUIREMENTS

NOTE

To achieve an installation with 0” (0 cm) clearance 

for the back of the dryer (for other than straight back 

venting), a quick-turn 90° dryer vent elbow must be 

installed as described previously in this manual.

Clearance requirements, continued

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

SIDES

REAR

TOP

FRONT

 Alcove

0” (0 cm) 0” (0 cm)* 0” (0 cm)

n/a

 Under-

 Counter

0” (0 cm) 0” (0 cm)* 0” (0 cm)

n/a

 Closet

0” (0 cm) 0” (0 cm)* 0” (0 cm)

1” (2.5 cm)

0”

(0cm)

0”

(0cm)

1”

(2.54cm)

0”

(0cm)

*  For other than straight back venting, a quick-turn 90° 

dryer vent elbow (vented right or down in free-standing 

dryer or right on pedestal-mounted dryer) must be 

installed to achieve 0” (0 cm) installation.

60 sq. in.

(387.1cm²)

3”

(7.6cm)

60 sq. in.

(387.1cm²)

3”

(7.6cm)

closet door

Installation in a Recess or Closet

  1  A dryer installed in a bedroom, bathroom, recess or 

closet, MUST be exhausted outdoors.

  2  No other fuel burning appliance shall be installed in 

the same closet as the gas dryer.

  3  Your dryer needs the space around it for proper 

ventilation.

DO NOT install your dryer in a closet with a solid door.
  4  Closet door ventilation required: A minimum 

of 120 square inches (774.2 cm²) of opening, 

equally divided at the top and bottom of the 

door, is required. Openings should be located 3 

inches (7.6 cm) from bottom and top of door. 

Openings are required to be unobstructed when a 

door is installed. A louvered door with equivalent 

air openings for the full length of the door is 

acceptable.