This product requires a three-prong grounded outlet.
The installer must perform a ground continuity check 
on the power outlet box before beginning the 
installation to ensure that the outlet box is properly
grounded. If not properly grounded, or if the outlet 
box does not meet electrical requirements noted 
(under ELECTRICAL REQUIREMENTS), a qualified
electrician should be employed to correct any
deficiencies.

CAUTION: For personal 
safety, remove house fuse 
or open circuit breaker 
before beginning 
installation to avoid severe 
or fatal shock injury.

CAUTION: For personal safety, the mounting surface 
must be capable of supporting the cabinet load, in 
addition to the added weight of this 63–85 pound
(28.5–38.5 kg) product, plus additional oven loads of
up to 50 pounds (22.7 kg) or a total weight of
113–135 pounds (51.3–61.2 kg).

CAUTION: For personal safety, this product cannot 
be installed in cabinet arrangements such as an island or 
a peninsula. It must be mounted to BOTH a top cabinet 
AND a wall.

NOTE: For easier installation and personal safety, it is 
recommended that two people install this product.
IMPORTANT – PLEASE READ CAREFULLY. FOR 
PERSONAL SAFETY, THIS APPLIANCE MUST BE 
PROPERLY GROUNDED TO AVOID SEVERE OR 
FATAL SHOCK.

The power cord of this
appliance is equipped with a 
three-prong (grounding) 
plug which mates with a 
standard three-prong 
(grounding) wall receptacle 
to minimize the possibility 
of electric shock hazard 
from this appliance.

You should have the wall receptacle and circuit checked
by a qualified electrician to make sure the receptacle is
properly grounded.

Where a standard two-prong wall receptacle is 
encountered, it is very important to have it replaced 
with a properly grounded three-prong wall receptacle,
installed by a qualified electrician.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT,
DEFORM OR REMOVE ANY OF THE PRONGS 
FROM THE POWER CORD. DO NOT USE WITH 
AN EXTENSION CORD.

IMPORTANT SAFETY INSTRUCTIONS

Ensure proper
ground exists
before use

Installation Instructions

EN-3

ELECTRICAL
REQUIREMENTS

Product rating is 120 volts AC, 60 Hertz, 15 amps and
1.6 kilowatts. This product must be connected to a

The power supply cord and plug should be brought to a

the prevailing local code for this kilowatt rating. 

the requirements of the National Electrical Code or 

voltage and frequency. Wire size must conform to

seperate and dedicated supply circuit of the proper 

seperate and dedicated 15- to 20- ampere branch 

National Electrical Code or the prevailing local code.

by a qualifed electrician and conform to the 

The outler box and supply circuit should be installed 

be located in the cabinet above the microwave oven. 

circuit single grounded outlet. The outlet box should 