INSTALLATION REQUIREMENTS

Installation in a Recess or Closet

1  A dryer installed in a bedroom, bathroom, recess or 

closet, MUST be exhausted outdoors.

2  No other fuel burning appliance shall be installed in 

the same closet as the gas dryer.

3  Your dryer needs the space around it for proper 

ventilation.

DO NOT install your dryer in a closet with a solid door.

4  Closet door ventilation required: A minimum 

of 120 square inches (774.2 cm²) of opening, 

equally divided at the top and bottom of the 

door, is required. Openings should be located 3 

inches (7.6 cm) from bottom and top of door. 

Openings are required to be unobstructed when a 

door is installed. A louvered door with equivalent 

air openings for the full length of the door is 

acceptable.

60 sq. in.

(387.1cm²)

3”

(7.6cm)

60 sq. in.

(387.1cm²)

3”

(7.6cm)

closet door

Manufactured or mobile home installation

1  Installation MUST conform to current Manufactured 

Home Construction & Safety Standard, Title 24 

CFR, Part 32-80 (formerly the Federal Standard 

for Mobile Home Construction and Safety, Title 24, 

HUD Part 280) or Standard CAN/CSAZ240 MH.

2  Dryer MUST be exhausted outside (outdoors, not 

beneath the mobile home) using metal ducting 

that will not support combustion. Metal ducting 

must be 4 inches (10.16 cm) in diameter with no 

obstructions. Rigid metal duct is preferred.

  3  If dryer is exhausted through the fl oor and area 

beneath the mobile home is enclosed, the exhaust 

system MUST terminate outside the enclosure with 

the termination securely fastened to the mobile 

home structure.

  4  Refer to previous sections in this guide for other 

important exhaust venting system requirements.

  5  When installing a gas dryer into a mobile home, a 

provision must be made for outside make up air. 

This provision is to be not less than twice the area 

of the dryer exhaust outlet.

  6  Installer MUST anchor this laundry center to the 

fl oor with approved Mobile Home Installation Kit - 

P/N 137067200.