Installation Instructions

Inlet Hoses

1

  Connect the straight ends of the white inlet hoses to the taps. 

(There are washers fitted in both ends).

2

  Connect the elbow ends of the white inlet hoses to the machine 

inlet valves. Inlet valves are marked on the back of the machine.

   

 

H = Hot   

C = Cold.

  Minimum height of taps to clear the top of the machine is 1150mm.

Cold Supply Only:
If you only have a cold water supply, an inlet valve cap (blanking cap) MUST be connected to the 
hot inlet valve. The cap prevents water leaking out of the hot valve. The cap is available from your 
Fisher & Paykel Dealer or Authorised Service Centre, Part No. 388491. This appliance incorporates 
backflow protection complying with AS3500.1. No further backflow protection is required for 
connection to the water supply.

Levelling Your Machine
It is IMPORTANT to level the machine to ensure even spin 
performance. 

1

  Separate the 4 rubber foot inserts from the moulding and 

fit into the feet on the base of the machine. 

2

  Move the machine to its final position.  (We suggest a 

minimum clearance of 20 mm each side).

3

  Adjust the feet so the machine is level and cannot rock.

To check if your machine is level:
Look down on the wash bowl and make sure it sits slightly forward of centre (see Diagram 1).

  Close the lid. Visually check that the lid fits evenly on both sides.  If it does not look like the 

diagram in the middle, adjust one of the feet slightly until it matches. The diagram on the top and 
bottom are not correct (see Diagram 2).

4

  Turn on the water and check all hose connections for leaks. Make sure there are no kinks in the hoses. 

5

  Uncoil power cord and plug into wall socket.

Tap end 

Machine end

Adjustable feet

Rubber insert

To check levelling look 
down on the wash bowl

Correct 

Incorrect 

Diagram 1

Lid Alignment

Lid

Topdeck

Wind right foot down 
(out) to correct

Wind left foot down 
(out) to correct

Lid

Lid

Topdeck

Topdeck

Diagram 2

 