SWGII-4CC CARRIER SIDEWALL POWER VENTING KIT 

Field Controls P/N 46205403, Carrier P/N KGASW03012SP 

 
Kit Includes: 

SWGII-4HD Sidewall Power Venter 
CK-43CC Control Kit 

Includes: 

4" MG-1 Barometric Draft Control 
Fan Proving Switch 
Fixed post purge 

 
For Use With The Following Carrier Furnace Models: 
 

58UXT 

58DXT 

58UXV 

58UHV 

58TUA 

58TMA 

58WAV 

58ZAV 

58PAV 

58RAV 

GB1AAV 

GB3AAV 

 
For Use With The Following BDP Furnace Models: 
 

330JAV 

331JAV 

333JAV 

333BAV 

330AAV 

331AAV 

395CAV 

376CAV 

383KAV 

373LAV 

480BAV 

481BAV 

GB1AAV  GB3AAV 

 
For All Single-Furnace Systems: 
Use one SWGII-4CC Kit for each furnace, and do not common-vent with other appliance(s).  To 
common-vent these furnaces with other appliances, use SWGII-4HD Kit with instruction P/N 
46139100 and a CK Series Control Kit for each appliance. 
 
For All Two-Stage furnaces: 
When setting up a two-stage furnace, the furnace should be operating on HIGH-STAGE HEAT while 
adjusting the sidewall power venter airflow adjustment damper, draft control, and proving switch. 
 

 
VENTING INSTALLATION OPTIONS 
 
FURNACE MODELS 

 

4-in. dia. Type B-1 vent up 

to 40 ft. long, up to 4 

elbows, and 1 tee § 

 

3-in. dia. Type B-1 vent up to 40 ft. 

long, up to 4 elbows, and 1 tee § 

 

Draft Safeguard 

Switch Assembly 

 
Two-Stage models 
58UXT    330JAV 
58DXT    331JAV 
58UXV    333JAV 
58UHV    333BAV 
58TUA    330AAV 
58TMA    331AAV 

 

PERMITTED WITH ALL 

GAS INPUT SIZES 

 

A 5"-to-4" reducer is 

required between furnace 

and vent for inputs greater 

than 105,000 Btu/hr. 

 

PERMITTED WITH ALL GAS 

INPUT SIZES ‡ 

 

A reducer is required between 

furnace and vent for these inputs: 

up through 105,000 Btu/hr 4"-to-3" 
more than 105,000 Btu/hr 5"-to-3". 

 

 

PERMITTED 

WITH OR 

WITHOUT THE 

DRAFT 

SAFEGUARD * 

 
Single-Stage models 
58WAV   395CAV 
58ZAV    376CAV 
58PAV    383KAV 
58RAV    373LAV 
GB1AAV 480BAV 
GB3AAV 481BAV 

 

PERMITTED WITH ALL 

GAS INPUT SIZES 

 

A 5"-to-4" reducer is 

required between furnace 

and vent for inputs greater 

than 115,000 Btu/hr. 

 

PERMITTED WITH GAS INPUTS 

OF 88,000 Btu/hr AND LESS ‡ 

 

A 4"-to-3" reducer is required 

between furnace and vent. 

 

 

PERMITTED 

ONLY WITH 

THE DRAFT 

SAFEGUARD † 

 