For Furnace Models GBI, GCI, GHI, GSI, and GUI 

BTU/Hr.  Diameter of 

Flue Collar 

on Furnace 

Installer 

Provided Flue 

Pipe Transition 

Size Diameters 

Maximum 

Equivalent Length 

(ft.) for 4" Vent Pipe 

Maximum 

Equivalent Length 

(ft.) for 5" Vent Pipe 

45,000 

3" 

3" to 4" 

100 

100 

70,000 

3" 

3" to 4" 

100 

100 

90,000 

3" 

3" to 4" 

100 

100 

115,000 

4" 

None 

85 

95 

140,000 

4" 

None 

65 

80 

 

For Furnace Models GMI 

BTU/Hr.  Diameter of 

Flue Collar 

on Furnace 

Installer 

Provided Flue 

Pipe Transition 

Size Diameters 

Maximum 

Equivalent Length 

(ft.) for 4" Vent Pipe 

Maximum 

Equivalent Length 

(ft.) for 5" Vent Pipe 

40,000 

3" 

3" to 4" 

100 

100 

60,000 

4" 

None 

100 

100 

80,000 

4" 

None 

100 

100 

100,000 

4" 

None 

100 

100 

120,000 

4" 

None 

80 

90 

140,000 

4" 

None 

60 

80 

 
General Wiring 

 

 

 
For complete installation information refer to the Field Controls SWG-4AM Power Venter Installation 
Manual for details (P/N 46333300.) 

 