Emerson 16E09-101 User's Manual

Emerson Refrigerators User's Manual - 16E09-101.
Download
Page  of 16
4.2, 1919 votes
background image

CONTENTS
Basic Description ........................................................   1
Precautions .................................................................   1
Installation ...................................................................   2
Wiring ..........................................................................   3
User Menu ..................................................................   4
Operation ....................................................................   5
Specifications ..............................................................   7
Troubleshooting ...........................................................   8

www.white-rodgers.com

www.emerson.com

PRECAUTIONS 

16E09-101

Universal Electronic Temperature Control

PART NO. 37-6857G

Replaces 37-6857F

1016

INSTALLATION AND

OPERATION INSTRUCTIONS

DESCRIPTION 
The 16E09-101 is a single stage electronic temperature con-
trol, with a Nema 1 rated enclosure, and can be used for most 
applications within the temperature control range of -40° to 
220°F, (-40° to 104°C). The control has an SPDT (Single Pole 
Double Throw) output load relay.
The control has user options to control differential, anti-short 
cycle delay, set back, offset, alarms and more. It includes an 
NTC (Negative Temperature Coefficient) thermistor tempera-
ture sensor, and can be used with certain other NTC or PTC 
(Positive Temperature Coefficient) thermistors that meet the 
specified resistance vs. temperature specifications. See the 
tables on page 7.
The control can fit many applications, which range from 
refrigeration to heating due to the wide temperature range of 
the control stated above. Typical applications include walk-
in freezers, beverage coolers, supermarket display cases 
for flowers, produce, meats, convenience store refrigerated 
cases, food warmers, boiler control, and certain industrial 
applications. 

Save these instructions for future use!

WARNING

!

16E09-101 Optional Accessories / Service Items:
Immerson Well  .................................................... F89-0286
Replacement 7.5' NTC Remote Sensor .............. F136-0114
Well Heat Transfer Compound ............................. F145-0163

•  Failure to read and follow all instructions carefully before 

installing or operating this control could cause personal 
injury and/or property damage.

•  To  prevent  electrical  shock,  personal  injury  and/or 

equipment damage, disconnect electric power to system 
at main fuse or circuit breaker box prior to installation 
or service.

•  To  prevent  scald  injury,  do  not  use  this  control  to 

heat  water  for  bathing,  washing,  hot  tub  or  similar 
applications.

•  Where  failure  of  this  control  may  result  in  personal 

injury and/or property damage, additional alarms or limit 
controls must be installed.

•  This control is a temperature control and is not to be 

used as a temperature limit control.

Related Manuals for Emerson 16E09-101

0.492899s