Emerson 167D Series Switching Valves Installation Guide

Emerson Regulators and Relief Valves Installation Guide - 167D Series Switching Valves.
Download
Page  of 4
4.3, 1915 votes
background image

www.fisherregulators.com

D103234XUS2

Installation Guide

English – June 2011

167D Series

Maximum Operating Inlet Pressure

(1) 

 

Types 167D and 167DS: 27,6 bar / 400 psig

 

Types 167DA and 167DAS: 8,6 bar / 125 psig

    

Types 167DA and 167DAS (NACE): 6,9 bar / 100 psig

Maximum Diaphragm Pressure

(1) 

 

10,3 bar / 150 psig over outlet pressure setting 

 

up to a maximum of 17,2 bar / 250 psig

Proof Test Pressure

All Pressure Retaining Components have been 

proof tested per Directive 97/23/EC - Annex 1, 

Section 7.4

Temperature Capabilities(1)

 

Nitrile (NBR) 

 

Standard Service (Types 167D and 167DA only):  

    -29° to 82°C / -20° to 180°F 

 

Low Temperature Service (Types 167D and 167DA 

       only) and Standard Service (Types 167DS and 

    167DAS only): -40° to 82°C / -40° to 180°F

 

Fluorocarbon (FKM)

 

High Temperature Service: -18° to 149°C / 

       0° to 300°F

Installation

!

WARNING

Only qualified personnel should install 

or service a switching valve.  Switching 

valves should be installed, operated, 

and maintained in accordance with 

international and applicable codes and 

regulations, and Emerson Process 

Management Regulator Technologies, 

Inc. instructions.
If the switching valve vents fluid 

or a leak develops in the system, it 

indicates that service is required.  

Failure to take the switching valve out 

of service immediately may create a 

hazardous condition.
Personal injury, equipment damage, 

or leakage due to escaping fluid or 

bursting of pressure-containing parts 

may result if this switching valve is 

overpressured or is installed where 

service conditions could exceed the 

limits given in the Specifications 

section, or where conditions exceed 

any ratings of the adjacent piping or 

piping connections.

Introduction
This installation guide provides instructions for 

installation, startup, and adjustment.  To receive a copy 

of the instruction manual, contact your local Sales 

Office or view a copy at www.fisherregulators.com. 

For further information refer to: Type 167D Series 

Instruction Manual, Form 5859, D103234X012.

P.E.D. Category
This product may be used as a safety accessory 

with pressure equipment in the following Pressure 

Equipment Directive 97/23/EC categories.  It may 

also be used outside of the Pressure Equipment 

Directive using sound engineering practice (SEP) 

per table below.

PRODUCT SIZE

CATEGORIES

FLUID TYPE

1/4 or 1/2 NPT

SEP

1

Specifications
Available Configurations

       

Types 167D and 167DS: Two-way 

       switching valves

    

Types 167DA and 167DAS: Three-way 

       switching valves
Body Size, Inlet and Outlet Connection Style 

    

Ports A and C: 1/4 or 1/2 NPT

    

Vent and Control Pressure Connections 

       (Port D) and Port B: 1/4 NPT
Outlet Pressure Ranges(1)

       Types 167D and 167DS (Two-Way  

       Switching Valves):

      Port A as Inlet: 

      0,21 to 1,0 bar / 3 to 15 psig(2) 

      0,34 to 1,4 bar / 5 to 20 psig 

      0,34 to 2,4 bar / 5 to 35 psig 

      1,7 to 4,1 bar / 25 to 60 psig 

      2,8 to 8,6 bar / 40 to 125 psig 

      3,4 to 10,3 bar / 50 to 150 psig(3)

      Types 167DA and 167DAS (Three-Way 

      Switching Valves):

    Port A or C as Inlet: 

      0,97 to 1,4 bar / 14 to 20 psig 

      1,1 to 2,4 bar / 16 to 35 psig

      1,7 to 4,1 bar / 25 to 60 psig

      2,8 to 8,6 bar / 40 to 125 psig

    Port B as Inlet: 

      0,48 to 1,4 bar / 7 to 20 psig

      0,69 to 2,1 bar / 10 to 30 psig

      1,7 to 3,4 bar / 25 to 50 psig

      2,8 to 6,2 bar / 40 to 90 psig

1.  The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.

2.  For Type 167D only

3.  For Type 167DS only.