SERVICE DATA SHEET

240389646

ICE & WATER - AUTOMATIC DEFROST

BOTTOM FREEZER - R134a 

IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. 
Untrained persons should not attempt to make repairs due to the possibility of electrical 
shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to 
their original position and properly secured.

 CAUTION

All electrical parts and wiring must be shielded from torch flame. DO NOT allow 
torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. 
Excessive heat will distort the plastic liner.

NOTE

This product comes equipped with an Adaptive Defrost Control (ADC). To activate manual 
defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) 
keys for 5 seconds. A “d” in the freezer temperature window and “F” in the refrigerator 
temperature window will display when the heater is activated. To deactivate manual 
defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) 
keys for 5 seconds. A “d” and “F” will be displayed until the defrost cycle is complete.

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING

Type A with Run/Start Capacitor

65°F (18°C) Ambient

90°F (32°C) Ambient

Operating Time

90 to 100%

100%

Freezer Temperature

-5° to 2° F (-20° to -17° C)

-1° to 3° F  (-18° to -16° C)

Refrigerator Temperature

34° to 39° F (1° to 4° C)

34° to 39° F  (1° to 4° C)

Low Side Pressure  

-2 to 6 psig  ( -14 to 41 kPa)

-2 to 6 psig  (-14 to 41 kPa)

High Side Pressure (last 1/3 cycle)

85 to 105 psig  (586 to 724 kPa)

120 to 135 psig  (827 to 931 kPa)

Wattage (last 1/3 cycle)

30 to 50

50 to 70

Amps (running)

.4 to .8

.7 to .9

Base Voltage

115 vac (127 vac max)

DEFROST SPECIFICATIONS

Cabinet Size

Thermostat

Heater

Cut-in

Cut-out

Watts

Ohms

26’ & 28’ SD, 23’ CD

25° F (-4° C)

47° F (8° C)

500

26.5

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

CONDENSER FAN MOTOR

Watts

RPM

Amps

3.1

1100 CW Opposite Shaft

0.03 Running

FREEZER ICE MAKER SPECIFICATIONS

Electrical

115 vac (127 vac max)

Thermostat

Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)

Heater Voltage

85 vac

OPTIONAL FREEZER ICE MAKER CONNECTOR PLUG

Wire Number

Wire Color

Connects to:

1

Green/Yellow

Ground

2

Yellow/Blue

Water Valve

3

Black/Orange

Line

4

Light Blue

Neutral

IMPORTANT
                                                                                                     
PLEASE RETURN THIS SHEET TO IT’S ORIGINAL LOCATION.

FREEZER ICE MAKER INFORMATION

Test Cycling: Remove cover by inserting screwdriver 

in notch at  bottom and prying cover from housing. Use 

screwdriver to rotate motor gear counterclockwise until 

holding switch circuit is completed. All components of ice 
maker should function to complete the cycle.  

Water Fill Volume: The water fill adjustment screw 

will change the fill time. One full turn is equal to 20cc 

(.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). 

When a water valve is replaced, the fill volume must be 

checked.      

TU

R

N

Mounting
Plate
Screws

Mounting
Plate
Screw

Motor
Gear

Timing

Gear

Water Fill
Adjustment

POWER

ICE MAKER

ICE

M

AKER

ICE
M

AKER

W

ATER
VA

LV

E

LINE

THERMAL

CUT-OUT

HOLD

SWITCH

THERMOSTAT

SHUT-OFF

SWITCH

WATER FILL

SWITCH

MOLD HEATER

MOLD

MOUNTING

PLATE

165 WATTS

MOTOR

NEUTRAL

BL

K/ORN

BL

K

BLK

BLK

BLU

C

C

C

NO

NO

NO

NC

NC

NC

LT. BLU

LT

.BL

U

BRN

RED

GRN / YEL

GR

N

/

YEL

RED

RE

D

YEL

YEL

/BL

U

YEL

P-3

P-1

P-4

P-2

ICE MAKER

Ice Maker Errors Displayed on “UI”

Diagnostic Mode

Note: See Service Manual for 

complete description.

ERROR

Test

Activate: Hold FF (+) and FZ (+) for 5 sec.

None

52C

Ice tray thermistor temperature displayed - OK, OP open, SH short

55C

Water valve test

57C

Fan test, on or off

58C

Ice level sensor switch test

63C

Harvest motor system test
De-activate: Hold FF (+) for 5 sec.

System Error Codes Displayed on “UI”

Diagnostic Mode

Note: See Service Manual for 

complete description.

ERROR

Test

Activate: FZ (+) and FZ (-) for 5 
sec.

OP or 2

Freezer Sensor OPEN

1

Standard compressor

22

Damper

SH or 3

Freezer Sensor SHORTED

2

Defrost heater

23

Fresh food door

OP or 2

FF Sensor OPEN

3

FF lighting

24

Freezer door

SH or 3

FF Sensor SHORTED

8

Water valve,water disp.

26

Defrost limit switch

SY

EF

Evaporator Fan Circuit

9

FZ lighting

28

Dispenser paddle

SY

CE

Communication error

10

Auger motor

36

Ice door

SY

CF

Communication error

11

Cube/crush solenoid

29

FF Thermistor

41

Perfect Temp Drawer

30

FZ Thermistor

12

VCC Condensor fan

33

Ambient Thermistor

To initiate manual defrost press and hold, for 5 sec. FF(+) and FF(-), (d) and (f) will 
be displayed.

38

VCC Compressor

0-

Software version

dF

In Manual Defrost  (See Note)

15

Evaporator fan
De-activate: Hold FF (+) for 5 sec.