Electrolux Cold Rooms

-2/+8º - 6,7/8 m³
Electrolux cold rooms are available in a large range of different sizes and functionalities. They are designed to 
work in tropical temperatures (+43ºC). The range consists of coolers (-2/+8ºC) with panels 60 mm in thickness, 
freezer cold rooms (-10/-21°C) with panels 100 mm in thickness and with built-in or remote refrigerating unit. 
The four models detailed on this sheet are cooler cold rooms with a usable volume of 6,7 to 8 cubic meters. 
Models come with panels and gas pre-charged cooling unit.

Shelving as accessory

CONSTRUCTION
• Very short assembly time. Expert 
refrigeration knowledge is not required 
for installation. 
• New vacuum injection technology 
which permits to have significant 
enhancement on the performances of the 
panels and high quality. 
• Panels are cladded inside and outside 
with anti-scratch prepainted galvinized 
steel. Polyurethane foam insulation. CFC 
and HCFC free. 
• Rounded internal and external corners. 
All edges are radiused. 
• Anti-slip walk-in floor. 
• The fast-fit centering system allows 
perfect alignment of the panels. These 
new fasteners are made of high resistant 
composite materials and guarantee 
perfect grip of all components. 
• Airtight panels connection. All sides of 
panels have PVC gasket foamed in place 
to assure airtight and secure fitting. Any 
other sealing between panels on site is 
eliminated. 

• The refrigeration unit is mounted on a 
modular panel for easy installation and 
quick set-up of the cold room. All the 
refrigeration units are tropicalized (+43°C) 
and use R404A refrigerant and are 
supplied with a high/low temperature 
alarm. 
• If the floor on which the cold rooms will 
be installed presents irregularities or 
unevenness up to 1 cm, then the surface 
of the floor should be levelled.
  
PERFORMANCES 
• Defrosting through heated gas with 
re-evaporation of defrosting water 
permits to reduce the total power 
installed, shorten defrosting time and 
limit the warming of the cold room. 
• All models are equipped with internal 
lighting (waterproof IP54) mounted on the 
refrigerating unit panel.
• The control panel includes: luminous 
ON/OFF switch, internal lighting switch, 
cold room functioning indicator, defrost 
cycle indicator, temperature and 
thermostat control with digital display.

• The right-hinged door is available as 
standard (left-hinged door on request) 
and constructed with smooth rounded 
profiles, cam-lift action hinges, airtight 
magnetic gasket and high insulation thus 
allowing to reduce energy and operating 
costs. 
• Newly designed handle complete with 
lock and interior safety release to prevent 
entrapment when the door is accidentally 
locked from outside. 
• HACCP monitoring is possible trough a 
serial port supplied on all models. 
• Conform to ruling European safety and 
hygiene standards and H marked. 