Dell PowerConnect J-EX8208 Quick Start Manual
Dell PowerConnect J-Series J-EX8208 Ethernet Switch Quick Start
To install and configure a Dell PowerConnect J-Series J-EX8208 Ethernet Switch
(regulatory model number EX8208), you need:
z
Mechanical lift
z
Adjustable mounting brackets (4 pieces) with 12 bracket screws (provided)
z
Mounting hardware to secure the chassis to your rack (provided)
z
Jumper cord and cord retainer for each power supply (provided)
z
Optional power cord tray (provided)
z
Grounding cable—minimum 6 AWG (13.3 mm²), minimum 60°C wire—with grounding
lug (provided) attached by a licensed electrician
z
Two screws and two washers to secure the grounding lug to the switch (provided)
z
Ethernet cable with an RJ-45 connector attached (provided)
z
Electrostatic discharge (ESD) grounding strap (provided)
z
Number 2 Phillips (+) screwdriver
z
Management host, such as a PC, with an Ethernet port
NOTE: These instructions are for four-post rack installation with a mechanical lift. For
more information about installation and other setup tasks, see the PowerConnect
J-EX8208 switch documentation at http://www.support.dell.com/manuals.
Part 1: Mount the Switch
1. Attach the grounding strap to your bare wrist and to the ESD point on the chassis.
2. Ensure that the rack is properly secured to the building in its permanent location.
NOTE: To mount multiple units on the rack, mount the heaviest unit at the bottom of the
rack and mount the others from bottom to top in order of decreasing weight.
3. With 8 mounting screws—and cage nuts and washers if your rack requires
them—install front and rear mounting brackets on the left side of the rack in the
lowest position that has 14 U space for the chassis (15 U if you install the power cord
tray).
4. With 6 bracket screws, connect the front and rear brackets.
5. Repeat Steps 3 and 4 for the front and rear brackets on the right side of the rack.
6. (Optional) With 4 mounting screws—and cage nuts and washers if required—attach
the power cord tray to the rack.
7. Using a mechanical lift, position the switch in the rack onto the mounting brackets you
installed in the rack, and align the bracket holes with the rack holes.
8. Install a mounting screw—and a cage nut and washer if required—in each of the
24 front-mounting bracket holes.
Part 2: Connect the Switch to Earth Ground
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in
which the switch is mounted.
2. Place the grounding lug attached to the grounding cable over the protective earthing
terminal on the left side of the chassis, and secure the lug to the terminal with the
screws and washers.
Part 3: Connect Power to the Switch
Power supplies come preinstalled in the chassis. For each power supply:
1. Ensure that the power supply is fully inserted and latched securely in the chassis.
2. Flip the Enable switch to the Standby position.
3. Squeeze the sides of the cord retainer clip. Insert the L-shaped clip ends into the
bracket holes on each side of the AC appliance inlet.
4. Insert the coupler end of the jumper cord into the AC appliance inlet.
5. Push the jumper cord into the slot in the adjustment nut. Turn the nut until it is against
the base of the coupler and the slot in the nut is turned 90° from the top of the switch.
6. If the AC power source outlet has a power switch, set it to the OFF (0) position.
7. Insert the jumper cord plug into the power source outlet.
8. If the AC power source outlet has a power switch, set it to the ON (|) position.
9. Verify that the INPUT OK LED on the power supply faceplate is lit and is on steadily.
10. Flip the power supply Enable switch to the “on” position.
Related Manuals for Dell PowerConnect J-EX8208
-
Dell Servers KVM 1081AD/ KVM 2161AD User's Manual
140 pages
-
Dell Servers KVM 2162DS User's Manual
188 pages
-
Dell Servers PowerEdge RAID Controller 6i Owner's Manual
156 pages
-
Dell Servers PowerEdge RAID Controller H200 Owner's Manual
92 pages
-
Dell Servers PowerEdge RAID Controller H710P Owner's Manual
87 pages
-
Dell Servers PowerEdge RAID Controller S110 Owner's Manual
76 pages
-
Dell Servers PowerEdge RAID Controller S300 Owner's Manual
110 pages
-
AudioCodes Servers MP-114 Installation Manual
44 pages
-
Lucent Technologies Servers Definity 6408D+ Owner's Manual
92 pages
-
Dell Servers Brocade 300 Administrator's Guide
666 pages
-
Dell Servers Brocade M5424 Administrator's Guide
108 pages
-
Dell Servers Dell Networking N2000 Series CLI Reference Guide
1823 pages
-
Dell Servers Dell Networking N3000 Series CLI Reference Guide
1823 pages
-
Dell Servers Dell Networking N3000 Series User's Manual
1460 pages
-
Dell Servers PowerConnect M8024-K Command Line Interface Guide
1780 pages
-
Dell Servers PowerEdge 1950 Owner's Manual
160 pages
-
Dell Servers PowerEdge 2800 Installation and Troubleshooting Guide
84 pages
-
Dell Servers PowerEdge 2850 User's Manual
29 pages
-
Dell Servers PowerEdge M1000E Command Line Reference Guide
428 pages
-
Dell Servers PowerEdge R730 Troubleshooting
6 pages
-
Dell Servers PowerVault TL2000 Compatibility Matrix
49 pages
-
Dell Servers PowerVault TL2000 User's Manual
306 pages
-
Lenovo Servers 388 User's Manual
248 pages
-
Iomega Servers Storcenter Pro NAS Server ix4-200r User's Manual
28 pages