Technical Service Manual 

CHAPTER 3 OPERATING RANGE 

 
Temperature rang for air conditioner 

z

  The preset temperature of the appliance ranges from 66

°F to 88°F. 

z

  The ambient temperature of the cooling only air conditioner ranges from 64.4

°F to 109.4°F. 

z

  The rated cooling operation test condition is as following. 

Indoor DB/WB temperature:      80

°F /67°F 

outdoor DB/WB temperature:  95

°F /75°F 

z

  The rated heating operation test condition is as following. 

z

  indoor DB/WB temperature:  20℃/Max.15℃ 

z

  outdoor DB/WB temperature:    7℃/6℃ 

 