Casio Casio Watch 5204 User's Manual

Casio Watches User's Manual - Casio Watch 5204.
Download
Page  of 1
4.8, 1957 votes
background image

1

Operation Guide 5203 5204

MA1010-EA

 Your watch may differ somewhat from the one shown in the illustration.

 

Minute hand

Hour hand

24-hour disk

Second hand

Day

Crown  

(Normal position)

First click  

(Setting Day)

Second click  

(Setting Time)

To set the time

 Pul  the crown out to the 

1. 

second click.

 At this time, the second 

 

hand wil  move to the  

12 o’clock position and 

stop there.

 Set the hands by rotating the 

2. 

crown. Rotate the crown to 

move the hands clockwise. 

Move the minute hand four or 

five minutes past the time you 

want to set, and then back it 

up to the proper setting.

 Make sure that you also 

 

set the 24-hour disk to the 

correct hour of the day.

 Push the crown back in to 

3. 

the normal position to restart 

timekeeping.

To set the day

 Pull the crown out to the first click.

1. 

 Set the day by rotating the crown towards you.

2. 

 Push the crown back in to the normal position.

3. 

 Avoid changing the date setting while the current time is between 9:00 p.m. and 

 

1:00 a.m. 

Using the Stopwatch

Stopwatch minute hand

This hand rotates and 

indicates the second 

count during the first  

60 seconds.

Stopwatch  

1/100 second hand

Stopwatch second 

hand

The stopwatch lets you measure elapsed time up to 59 minutes, 59.99 seconds.

To measure elapsed time (First 60 seconds)

 Press 

1. 

A

 to start the stopwatch.

 Press 

2. 

A

 to stop the stopwatch.

 You can resume the measurement operation by pressing 

 

A

 again.

 Check the elapsed time.

3. 

 The example below shows an elapsed time of 40.30 seconds.

 

Stopwatch 1/100 second hand 

[30]

Stopwatch second hand 

[40 seconds]

 Press 

 

B

 to reset the stopwatch. 

This will enter the Timekeeping Mode.

To measure elapsed time (After the first 60 seconds)

 Press 

1. 

A

 to start the stopwatch.

 During elapsed time measurement, the stopwatch 1/100 second hand 

 

automatically rotates for the final second of each minute.

Press 

2. 

A

 to stop the stopwatch.

 You can resume the measurement operation by pressing 

 

A

 again.

 Press 

3. 

A

 and the stopwatch 1/100 second hand wil  move to the  

1/100 second count.

 If the elapsed time operation was stopped during the final second of each 

 

minute, the stopwatch 1/100 second hand will already be pointing at the  

1/100 second count. Do not press A at this time, because doing so will 

restart the elapsed time operation.

 Check the elapsed time.

4. 

 The example below shows an elapsed time of two minutes, 40.30 seconds.

 

Stopwatch 1/100 second hand 

[30]

Stopwatch second hand 

[40 seconds]

Stopwatch minute hand 

[2 minutes]

 Press 

 

B

 to reset the stopwatch. 

This will enter the Timekeeping Mode.

Notes:

 Do not try to perform stopwatch operations while the crown is pulled out either 

 

to the first or second click. If you try to press a button, you might accidental y 

cause the crown to rotate and change the current time or day setting.

 If the starting positions of the stopwatch second hand and 1/100 second hand 

 

become misaligned, use the fol owing procedures to adjust the positions of the 

hands so they point to 12 o’clock when the stopwatch is reset.

To adjust the positions of the stopwatch hands

 Press 

1. 

B

 to reset the stopwatch, and check the alignment of the stopwatch 

second hand and 1/100 second hand.

 Pull out the crown to the second click.

2. 

 Press 

3. 

A

 to move the stopwatch 1/100 second hand.

 If the stopwatch minute hand is aligned correctly, proceed to step 5. If the 

4. 

stopwatch minute hand is also misaligned, press B to move the stopwatch 

second hand.

 After making the adjustments you want, push the crown back in to its normal 

5. 

position.

 Note that pulling the crown out also stops the timekeeping second hand. After 

 

performing the above procedure, you should also adjust the timekeeping setting.

For a watch with an elapsed time bezel  

 

Rotate the elapsed time bezel to align the 

 mark with the 

minute hand. 

After certain amount of time elapsed, read the graduation on 

the elapsed time bezel which the minute hand points to. 

The elapsed time is indicated.

Elapsed time bezel

 Some water resistant models are equipped with a screw 

 

lock crown.

 With such models, you must unscrew the crown in the 

 

direction noted in the illustration to loosen it before you can 

pull it out. Do not pull too forcibly on such crowns.

 Also note that such watches are not water resistant while 

 

their crowns are loosened. Be sure to screw the crowns 

back in as far as they will go after making any setting.

Specifications

Accuracy at normal temperature:  ± 20 seconds a month
Display:  3 analog hands (timekeeping hour and minutes, stopwatch 1/100 seconds), 

3 dials (timekeeping 24-hour and seconds, stopwatch minutes), day

Stopwatch function:  Measuring capacity: 59'59.99"/Measuring unit: 1/100 second 

Measuring modes: Elapsed time

Battery:  One silver oxide battery (Type: SR927W)

Approximately 2 years on type SR927W (assuming one stopwatch operation 60 min./

day)

0.583682s