Carrier 48TC**16 User's Manual

Carrier Air Conditioners User's Manual - 48TC**16.
Download
Page  of 48
4.6, 1310 votes
background image

48TC**16

Single Package Rooftop

Gas Heating/Electric Cooling Unit

with Puron(R--410A) Refrigerant

Size 16

Installation Instructions

NOTE: Read the entire instruction manual before starting

the installation

TABLE OF CONTENTS

SAFETY CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . . . .

INSTALLATION

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Jobsite Survey

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 1 - Plan for Unit Location

4

. . . . . . . . . . . . . . . . . .

Roof Mount

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 2 - Plan for Sequence of Unit Installation

5

. . . . . .

Curb- Mount Installation

5

. . . . . . . . . . . . . . . . . . . . .

Pad- Mount Installation

5

. . . . . . . . . . . . . . . . . . . . . .

Frame- Mount Installation

5

. . . . . . . . . . . . . . . . . . . .

Step 3 - Inspect Unit

5

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Step 4 - Provide Unit Support

5

. . . . . . . . . . . . . . . . . . .

Roof Curb Mount

5

. . . . . . . . . . . . . . . . . . . . . . . . . .

Slab Mount (Horizontal Units Only)

5

. . . . . . . . . . .

Alternate Unit Support

(In Lieu of Curb or Slab Mount)

5

. . . . . . . . . . . . . .

Step 5 - Field Fabricate Ductwork

7

. . . . . . . . . . . . . . . .

Step 6 - Rig and Place Unit

7

. . . . . . . . . . . . . . . . . . . . .

Positioning on Curb

8

. . . . . . . . . . . . . . . . . . . . . . . .

Step 7 - Convert to Horizontal and Connect Ductwork

8

. . .

Step 8 - Install Outside Air Hood

9

. . . . . . . . . . . . . . . .

Economizer Hood Removal and Setup —

Factory Option

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Two Position Damper Hood Removal and Setup —

Factory Option

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Economizer Hood and Two- Position Hood

10

. . . . .

Step 9 - Install Flue Hood

10

. . . . . . . . . . . . . . . . . . . . .

Step 10 - Install Gas Piping

11

. . . . . . . . . . . . . . . . . . . .

Factory- Option Thru- Base Connections

(Gas Connections)

11

. . . . . . . . . . . . . . . . . . . . . . . . .

Step 11 - Install External Condensate Trap and Line

13

. .

Step 12 - Make Electrical Connections

14

. . . . . . . . . . .

Field Power Supply

14

. . . . . . . . . . . . . . . . . . . . . . . .

All Units

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Units without Factory- Installed Disconnect

15

. . . .

Units with Factory- Installed Disconnect

15

. . . . . . .

Convenience Outlets

16

. . . . . . . . . . . . . . . . . . . . . . .

Factory- Option Thru- Base Connections

(Electrical Connections)

18

. . . . . . . . . . . . . . . . . . . .

Units without Thru- Base Connections

18

. . . . . . . . .

Field Control Wiring

18

. . . . . . . . . . . . . . . . . . . . . . .

Thermostat

18

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unit without Thru- Base Connection Kit

19

. . . . . . .

Heat Anticipator Settings

19

. . . . . . . . . . . . . . . . . . .

Humidi- MiZerR Control Connections

20

. . . . . . . . . .

Humidi- MiZer - Space RH Controller

20

. . . . . . . .

PremierLinkt (Factory Option)

21

. . . . . . . . . . . . . . . . .

Supply Air Temperature (SAT) Sensor

25

. . . . . . . . .

Outdoor Air Temperature (OAT) Sensor

25

. . . . . . .

EconoMi$er2

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Field Connections

25

. . . . . . . . . . . . . . . . . . . . . . . . . .

Space Sensors

27

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Connect Thermostat

27

. . . . . . . . . . . . . . . . . . . . . . .

Configure the Unit for Thermostat Mode

27

. . . . . .

Economizer Controls

28

. . . . . . . . . . . . . . . . . . . . . . . .

Indoor Air Quality (CO2 sensor)

28

. . . . . . . . . . . . .

Outdoor Air Quality Sensor

28

. . . . . . . . . . . . . . . . .

Space Relative Humidity Sensor or

Humidistat Connections

29

. . . . . . . . . . . . . . . . . . . .

Smoke Detector/Fire Shutdown (FSD)

30

. . . . . . . . .

Filter Status Switch

30

. . . . . . . . . . . . . . . . . . . . . . . .

Supply Fan Status Switch

30

. . . . . . . . . . . . . . . . . . .

Remote Occupied Switch

30

. . . . . . . . . . . . . . . . . . .

Power Exhaust (output)

30

. . . . . . . . . . . . . . . . . . . . .

CCN Communication Bus

31

. . . . . . . . . . . . . . . . . .

RTU Open Control System

32

. . . . . . . . . . . . . . . . . . . . .

Supply Air Temperature (SAT) Sensor

35

. . . . . . . . .

Outdoor Air Temperature (OAT) Sensor

35

. . . . . . .

EconoMi$er2

35

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Field Connections

35

. . . . . . . . . . . . . . . . . . . . . . . . . .

Space Temperature (SPT) Sensors

36

. . . . . . . . . . . .

Indoor Air Quality (CO2) Sensor

36

. . . . . . . . . . . . .

Related Manuals for Carrier 48TC**16

0.643330s