Carrier 38AK008 User's Manual | Page 5

Carrier Dryer User's Manual - 38AK008.
Download
Page  of 16
4.1, 2201 votes
background image

5

UNIT 38

DIM. A

DIM. B

DIM. C

DIM. D

DIM. E

DIM. F

AK007

1

′-61/2″

[470.0]

1

′-23/4″

[375.0]


1

′-21/4″

[362]

1

′-45/16″

[415]

2

′-95/16″

[846.5]

AK008

1

′-8″

[508.0]

1

′-61/2″

[470.0]


1

′-3″

[381]

2

′-5/16″

[613]

3

′-57/16″

[1052.5]

AK012

1

′-9″

[533.4]

1

′-8″

[508.0]

2

′-0″

[609.6]

1

′-3″

[381]

2

′-5/16″

[613]

3

′-57/16″

[1052.5]

AKS008

1

′-6″

[457.2]

1

′-43/4″

[425.5]

2

′-913/16″

[858.8]

1

′-3″

[381]

2

′-5/16″

[613]

3

′-57/16″

[1052.5]

AKS009

1

′-7″

[482.6]

1

′-5″

[431.8]

2

′-913/16″

[858.8]

1

′-3″

[381]

2

′-5/16″

[613]

3

′-57/16″

[1052.5]

AKS012

1

′-7″

[482.6]

1

′-5″

[431.8]

2

′-913/16″

[858.8]

1

′-3″

[381]

2

′-5/16″

[613]

3

′-57/16″

[1052.5]

NOTES:
1. Dimensions in [

 ] are in millimeters.

2.

Center of Gravity. See chart for 
dimensions.

3.

Direction of Airflow.

4. Minimum clearance (local codes or jurisdiction

may prevail):

a. Condenser coil, for proper airflow, 36 in. [914]

one side, 12 in. [305] the other. The left or rear
side getting the greater clearance is optional.

b. Overhead, 60 in. [1524] to assure proper con-

denser fan operation.

c. Between units, control box side, 42 in. [1067]

per NEC (National Electrical Code) (U.S.A.
Standard).

d. Between unit and ungrounded surfaces, con-

trol box side, 36 in. [914] per NEC.

e. Between unit and block or concrete walls and

other grounded surfaces, control box side,
42 in. [1067] per NEC.

5. With the exception of the clearance for the con-

denser coil as stated in Note 4b, a removable
fence or barricade requires no clearance.

6. Units may be installed on combustible floors

made from wood or Class A, B, or C roof covering
material.

ELECTRICAL CONNECTIONS

SERVICE VALVE CONNECTIONS — 50/60 Hz

CONNECTION SIZES

AA

13/8″ Dia [35] Field Power Supply Hole

BB

2

″ Dia [51] Power Supply Knockout

CC

21/2″ Dia [64] Power Supply Knockout

DD

7/8″ Dia [22] Field Control Wiring Hole

UNIT 38

SUCTION

LIQUID

AK007

11/8″ [28.6]

11/2″ [12.7]

AK008

11/8″ [28.6]

11/2″ [12.7]

AK012

11/8″ [28.6]

15/8″ [15.9]

AKS008

11/8″ [28.6]

11/2″ [12.7]

AKS009

11/8″ [28.6]

15/8″ [15.9]

AKS012

11/8″ [28.6]

15/8″ [15.9]

Fig. 2 — Dimensions (ft-in.)

Fig. 3 — Rigging Label

*Weights are for aluminum coils.

UNIT

38

RIGGING
WEIGHT*

A

B

C

lb

kg

in.

mm

in.

mm

in.

mm

AK007

390

176

45.0

1143

38.5

978

35.5

904

AK008

442

200

45.0

1143

38.5

978

43.5

1105

AK012

476

215

45.0

1143

38.5

978

43.5

1105

AKS008

560

254

45.0

1143

38.5

978

43.5

1105

AKS009

614

279

45.0

1143

38.5

978

43.5

1105

AKS012

614

279

45.0

1143

38.5

978

43.5

1105