Bryant PLUS 90X 353AAV User's Manual | Page 7

Bryant Furnace User's Manual - PLUS 90X 353AAV.
Download
Page  of 22
4.3, 2183 votes
background image

7

17

5 ⁄

16

"

24

1 ⁄

2"

27

9 ⁄

16

"

TYP

27

5 ⁄

8"

29

1

1 ⁄

16

"

TY

P

30

13

⁄16

"

32

5 ⁄

8"

TY

P

33

1 ⁄

4"

TYP

CONDENSA

TE

DRAIN TRAP

LO

C

A

TION

(AL

TERN

A

TE

UPF

LO

W)

7 ⁄

8-IN

. D

IA

A

CCES

SO

R

Y

PO

WER ENT

R

Y

7 ⁄

8-IN.

 DIA

PO

WER CONN

CONDENS

A

TE DRAIN

TRAP

 LO

C

A

TION

(D

OW

N

F

L

O

W &

HORIZONT

A

L L

E

F

T

)

26

15

⁄16

"

24

1 ⁄

2"

22

5 ⁄

16

"

2

-IN.

 COM

B

USTION-

AIR CONN

1 ⁄

2-IN.

 DI

A

GAS CONN

2

-IN

. VEN

T

 CONN

1 ⁄

2-IN

. D

IA

 THERMOST

A

T

ENT

RY

22

1

1 ⁄

16

"

SIDE INLET

23

1 ⁄

4"

TY

P

SIDE INLET

1

1 ⁄

4"

1

"

E

INLE

T

11

⁄16

"

11

⁄16

"

D

13

⁄16

"

13

⁄16

"

OUTLET

A

AIRF

LO

W

OUTLET

26

15

⁄16

"

28

1 ⁄

2"

22

5 ⁄

16

"

19

"

13

⁄16

"

5 ⁄

8"

5 ⁄

16

"

1

"

39

7 ⁄

8"

22

1 ⁄

4"

TYP

11

⁄16

"

7 ⁄

16

"

24

3 ⁄

16

"

B

O

T

T

OM INLET

18

1 ⁄

4"

22

1

1 ⁄

16

"

CONDENS

A

TE DRAIN

TRA

P

 L

OC

A

TION

(DO

WNF

LO

W &

HORIZONT

AL

 RIGHT)

OR AL

TERN

A

TE

1 ⁄

2-IN.

 DI

A

 GAS CONN

2-IN.

 COM

B

USTION-

AIR CONN

1 ⁄

2-IN

. DI

A

GAS CONN

7 ⁄

8-IN.

 DIA

PO

WER CONN

1 ⁄

2-IN

. DI

A

THERMOS

TAT

 EN

TR

Y

2-IN

. VEN

T

 CONN

DIMPLE L

OC

A

T

ORS

FOR HORIZONT

AL

HANGING

14

1 ⁄

2"

TY

P

SIDE INLET

NO

TES:

1.

Mini

m

um retu

rn-air openings at fur

nace

, based on metal duct.

 If fle

x duct is used,

see fle

x duct ma

n

u

facturer‘s recommendation

for equi

valent diameter

s

.

2.

Mini

m

um retu

rn-air opening at fur

nace:

a.

F

or 800 CFM 16-in

. (406mm)

 round or 14

1 /

(368mm) 

 x 12-in

. (305mm)

 rectangl

e.

b

.

F

or 1200 CFM 20-in

. (508mm)

 round or 14

1 /

(368mm)

 x 19

1 /

2-in. (495mm)

 rectangle

.

c.

F

or 1600 CFM 22-in

.(559mm)

 round or 14

1 /

(368mm)

 x 23

1 /

4-in

.(591mm)

 rectangl

e

.

d.

F

or airflo

w requirements ab

o

ve 1800 CFM, see 

Air Deli

ve

ry tab

le in Product Data

lite

rature f

or specific use of single side inlet

s

. The use of both side inlets

, a

combination of 1 side and the bottom, or the bottom only will e

nsure adequate

retur

n air openings f

or airflo

w requirements abo

ve 1800 CFM at 0.5 in. W

.C. ESP

.

9

7 ⁄

16

"

TYP

26

15

⁄16

"

TY

P

CONDENS

A

TE

DRAIN L

OC

A

TION

(UPFLO

W)

30

1 ⁄

2"

9 ⁄

16

"

TYP

CONDENSA

TE

DRAIN L

OC

A

TION

(UPF

L

O

W)

26

1 ⁄

4"

26

1 ⁄

4"

(684mm)

(667mm)

(666mm)

(567mm)

(51mm)

(51mm)

(13mm)

(13mm)

(576mm)

(368mm)

(32mm)

(25mm)

(591mm)

(684mm)

(240mm)

(440mm)

(622mm)

(700mm)

(702mm)

(754mm)

(783mm)

(829mm)

(845mm)

(22mm)

(22mm)

(21mm)

(21mm)

(17mm)

(17mm)

(464mm)

(775mm)

(565mm)

(614mm)

(25mm)

(1

1mm)

(17mm)

(1013mm)

(8mm)

(16mm)

(21mm)

(14mm)

(483mm)

(567mm)

(667mm)

(694mm)

(724mm)

UNI

T

 S

IZ

E

A

D

E

040-12 /

 036040

1

7-1/

2 (

445)

15-7/

8 (403)

16 (406)

060-12 /

 036060

17-1/

2 (445)

15-7/

8 (

4

03)

16 (406)

080-12 /

 036080

17-1/

2 (445)

15-7

/8

 (

40

3)

16 (4

06)

080-16 /

 048080

17-1/

2 (445)

15-7/

8 (403)

16 (406)

100-20 /

 060100

21 (25

.4)

19-3/

8 (492)

19-1/

2 (

4

95)

120-20 /

 060120

24-1/

2 (622

)

22-7/

8 (581)

23 (584)

A08321

353AA

V

 