580F units are a single piece, gas heating/electric
cooling unit, with a low profile, pre-wired, tested
and charged at the factory. The units have the
capability for convertible supply and return open-
ings and are intended for installation on an acces-
sory curb (ordered separately), or for slab mounting
(for horizontal duct connections). Units are
designed to accept a field-installed economizer,
enthalpy control, manual or 2-position outside air
damper, roof curb, as well as up to 3 choices of gas
heat. Refer to accessory chart for full listing.

FEATURES

• Standard one-year full product warranty.
• Five-year protection plan for the motor-

compressor.

• Five-year protection plan on heat exchangers.
• Outdoor ambient cooling operation from 25 F

(–4 C) to 115 F (46 C).

• Units are tested and certified by ARI and certi-

fied by UL and CSA. Factory-run test printout
included in each rooftop.

• 24-volt control circuit, with resettable breaker.
• Two-inch disposable-type return air filters in ded-

icated rack.

• Hermetic compressor on independent circuit with

internal line break and overload protection, self-
lubricating with internal discharge muffler.

• Refrigeration circuit contains a filter drier to trap

dirt and particles.

• Two-speed direct-drive evaporator fan on

sizes 036-060. All other sizes are belt driven.
Adjustable belt-drive fans are optional on 036-
060 sizes.

• Non-corrosive condensate pan with self-draining

design with both bottom and side drain
connections.

• Thru-the-bottom power, control and gas entry

capability.

• Indoor and outdoor coils constructed of alumi-

num fins mechanically bonded to seamless
copper tubes.

• Single point electrical and gas connections.
• Direct-drive propeller condenser fan totally

enclosed with permanently lubricated bearings.

• Pre-painted, insulated cabinet with primed inner

panels, certified 500-hr salt spray test and non-
corrosive screws.

• Large, easily removable panels provide ready

access to unit components for rapid removal or
maintenance.

SUBMITTAL DATA

Job Name ______________________________________

Architect _______________________________________

Engineer _______________________________________

Contractor

_____________________________________

Unit Designation _________________________________

PERFORMANCE DATA

Cooling

Net Total Cap. ________________________________ Btuh

Net Sensible Cap. _____________________________ Btuh

Compressor Power Input _________________________ kW

_______________________________ F Outdoor Air Temp.

Indoor Entering Air    db_________ F

wb  _________ F

CFM ____________

Ext. Static Pressure ____ (in. wg)

Fan RPM  ____________________________________ Bhp

SEER/EER______________________________________

Heating

Input:

Stage 1  ______________ Total ___________ Btuh

Output: Stage 1 ______________ Total ___________ Btuh

AFUE _________________________________________ %

Steady State  ___________________________________ %

Operating Weight  ________ lbs. (unit) _______ lbs. (curb)

ELECTRICAL DATA

Power Supply to Unit ______ Volts _____ Phase _____ Hz

Minimum Circuit Amps ______________

Maximum Overcurrent Protection (Fuse Only) ___________

HEATING & COOLING SUBMITTAL

DuraPac Series

Unit 580F036-150

3 to 121/

2 NOMINAL TONS

COMMERCIAL SINGLE-PACKAGE

ROOFTOP GAS HEATING/

ELECTRIC COOLING UNITS