Bryant Direct-Vent Downflow Condensing Gas for Manufactured Housing 351DAS User's Manual
Form No. PDS 351D.80.1
DIRECT-VENT DOWNFLOW
CONDENSING GAS FURNACE
for MANUFACTURED HOUSING
351DAS
Size 080
Series A
Utilizing the extensive resources available to Bryant, a new
standard of excellence has been achieved with the model
351DAS Downflow Furnace for manufactured (mobile) or
modular homes.
The model 351DAS is a unique downflow condensing fur-
nace with features like no other product in its class. The
351DAS builds on the many Bryant successes in the furnace
industry and establishes a new standard for high-efficiency
gas furnaces.
FEATURES
Factory Configuration
—Factory configured for downflow ap-
plications in manufactured (mobile) or modular homes.
The model 351DAS is available in 3 heat/airflow combina-
tions.
Sealed Combustion (Direct-Vent) System
—Enclosed burner
assembly isolates operating noise without the expense of
sound deadening devices. The sealed combustion (direct-
vent) system brings outdoor air directly into the combustion
chamber, reducing infiltration of cold air into the structure and
reducing heat loss.
3-Pass Primary Heat Exchangers
—This design accelerates
heat transfer and extracts heat that conventional heat ex-
changers waste up the flue. The weld-free primary heat ex-
changers are made of aluminized steel for corrosion
resistance.
Flow-Through Secondary Heat Exchangers
—Each cell is lami-
nated with our patented Everlastic
TM
polypropylene for greater
resistance to corrosion. This breakthrough in heating technology
helps extend the life of the furnace for years of trouble-free per-
formance.
Warranty
—Limited 20-year Warranty on the heat exchangers
for the original owner in single family residence. Contact your
dealer for details. Two-year limited parts and labor warranty on
entire unit.
Monoport Inshot Burners
—Produce precise air-to-gas mixture
which gives a clean burn. The large monoport on the inshot or
injection-type burners seldom, if ever, needs cleaning.
Control Center
—The printed-circuit board and all internal wiring
are factory installed. Convenient terminals permit quick-connec-
tion of a thermostat, a humidifier, an air cleaner, and air condi-
tioning control circuits.
As an added feature, the control has a built-in status indicator
and self-test feature. The status indicator flashes to indicate a
problem condition and assists the servicer in diagnosis. The self-
test feature allows for a complete check of the major compo-
nents in only seconds.
Combustion Air and Ventilation
—The 351DAS advanced design
allows Schedule 40PVC, PVC-DWV, SDR-21 PVC, SDR-26
PVC (not approved in Canada), ABS-DWV, or ABS-F628
Schedule 40 pipe to bring outdoor air into the furnace for com-
bustion. The extracted heat lowers the temperature of the com-
bustion products to a point (typically below 115°F) that any of the
approved types of pipe can also be used for venting combustion
products outside the structure. The combustion-air and vent
pipes can terminate through a side wall or through the roof when
using 1 of our approved vent termination kits.
Fully-Insulated Casing
—Foil-faced insulation in the heat ex-
changer section cuts heat loss, and insulation in the blower sec-
tion reduces noise levels. The casing also has the required
openings for left- or right-side connection of gas, electric, drain,
and vent connections.
Certifications
—The 351DAS units are A.G.A. and C.G.A. design
certified for use with natural and propane gases, as well as
GAMA efficiency rating certified. The furnace is factory-shipped
for use with natural and propane gases. (All parts necessary to
convert the gas valve for propane gas use are shipped with the
furnace.) Model 351DAS is design certified for installation in
manufactured (mobile) homes.
Quality Registration
—The 351DAS is engineered and manu-
factured under an ISO 9001 registered quality system.
Related Manuals for Bryant Direct-Vent Downflow Condensing Gas for Manufactured Housing 351DAS
-
Bryant Furnace PLUS 90X 353AAV User's Manual
22 pages
-
Bryant Furnace 310AAV Service Manual
45 pages
-
Bryant Furnace 915SA Product data
16 pages
-
Bryant Furnace 350MAV User's Manual
12 pages
-
Bryant Furnace PLUS 95S 355CAV Owner's Manual
14 pages
-
Carrier Furnace WEATHERMAKER 8000 58ZAV Instruction Manual
24 pages
-
Coleman Furnace DGAA User's Manual
14 pages
-
Goodman Mfg Furnace GMS90453BXA Parts list
11 pages
-
Rheem Furnace CRITERION II Installation Manual
8 pages
-
Trane Furnace XR 90 SERIES Owner's Manual
16 pages
-
Carrier Furnace 58GS User's Manual
12 pages
-
Carrier Furnace 58MCB User's Manual
12 pages
-
Rinnai Furnace ENERGYSAVER ES38 User's Manual
44 pages
-
Bryant Furnace Condensing s 398AAV User's Manual
12 pages
-
Thermo Products Furnace Thermo Pride Furnace OL6RA072D48(B/R) User's Manual
75 pages
-
Thermo Products Furnace OL5-85 User's Manual
32 pages
-
Thermo Products Furnace Thermo Pride Furnace MHA1-75N User's Manual
61 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8940 User's Manual
7 pages
-
Westinghouse Furnace FG7TC 95.1% AFUE Two-Stage Technical Literature
8 pages
-
Maytag Furnace PGC2TC PGC2TL | Maytag M1200 95.1% AFUE Two-Stage Fixed-Speed Gas Furnace Technical Literature
8 pages
-
Rinnai Furnace EX22C (RHFE-559FTA) Installation and Operation Manual
84 pages
-
York Furnace TM9Y Technical Guide
4 pages
-
York Furnace TM9E User's Manual
8 pages
-
GAMA Furnace Gas-Fired Furnace User's Information Manual
40 pages