SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, mainte-
nance, or use can cause carbon monoxide poisoning, explo-
sion, fire, electrical shock, or other conditions which may
cause personal injury or property damage. Consult a qualified
installer, service agency, local gas supplier, or your distribu-
tor or branch for information or assistance. The qualified
installer or agency must use only factory-authorized and
listed kits or accessories when modifying this product. Failure
to follow this warning could result in electrical shock, fire,
personal injury, or death.

Application of this furnace should be indoors with special
attention given to vent sizing and material, gas input rate, air
temperature rise, unit leveling, and unit sizing. Improper
installation or misapplication of furnace can require excessive
servicing or cause premature component failure.

Installing and servicing heating equipment can be hazardous due to
gas and electrical components. Only trained and qualified
personnel should install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations must
be performed by trained service personnel. When working on
heating equipment, observe precautions in literature, on tags, and
on labels attached to or shipped with unit and other safety
precautions that may apply.

These instructions cover minimum requirements and conform to
existing national standards and safety codes. In some instances,
these instructions exceed certain local codes and ordinances,
especially those that may not have kept up with changing residen-
tial construction practices. We require these instructions as a
minimum for a safe installation.

Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when han-
dling parts. Failure to follow this caution could result in
personal injury.

Wear safety glasses and work gloves. Have fire extinguisher
available during start-up and adjustment procedures and service
calls.

This is the safety-alert symbol

. When you see this symbol on

the furnace and in instructions or manuals, be alert to the potential
for personal injury.

Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies a hazard
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which would result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.

1. Use only with type of gas approved for this furnace. Refer to

the furnace rating plate.

2. Install this furnace only in a location and position as specified

in the “Location” section of these instructions.

3. Provide adequate combustion and ventilation air to the furnace

space as specified in “Air for Combustion and Ventilation”
section.

4. Combustion products must be discharged outdoors. Connect

this furnace to an approved vent system only, as specified in
the “Venting” section of these instructions.

5. Never test for gas leaks with an open flame. Use a commer-

cially available soap solution made specifically for the detec-
tion of leaks to check all connections, as specified in the “Gas
Piping” section.

NOTES:
1. Two additional 7/8-in. diameter holes are located in the top plate.
2. Minimum return-air openings ar furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.

a. For 800 CFM-16-in. round or 14 1/2 x 12-in. rectangle.
b. For 1200 CFM-20-in. round or 14 1/2 x 19 1/2-in. rectangle.
c. For 1600 CFM-22-in. round or 14 1/2 x 22-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific
use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the
bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.

→ Fig. 1—Dimensional Drawing

A02304

28-7/8"

25-1/4"

22-9/16"

JUNCTION BOX

LOCATION

7/8" DIA

ACCESSORY

1/2" DIA THERMOSTAT

WIRE ENTRY

3-15/16"

LEFT HAND GAS 

ENTRY

33-5/16"

24-7/8"

5-1/2"

7/8" DIA. ACCESSORY

11/16"

21-5/8"

BOTTOM INLET

1-11/16"

13/16"

11/16"

1-9/16"

2-9/16"

4-13/16"

AIRFLOW

19"

OUTLET

13/16"

11/16"

8-7/16"

1-7/16"

ALTERNATE

JUNCTION BOX

LOCATION (TYP)

VENT OUTLET

5 PLACES (TYP)

3-3/4"

1-1/2" DIA.

RIGHT HAND 

GAS ENTRY

1/2" DIA. THERMOSTAT

WIRE ENTRY

SIDE INLET

14-7/8"

7/8" DIA. ACCESSORY

1-1/4"

1"

22-1/16"

A

D

F

E

2

 

0.553701s