49

LK3-B434E Mark II

q

DIPB-1

DIPB-2

DIPB-3

DIPB-4

DIPB-5

DIPB-6

DIPB-7

DIPB-8

Motion when set to ON

First two stitches are sewn at a low speed of 260 rpm.

Last two stitches are sewn at a low speed of 260 rpm.

Last two stitches are sewn at a low speed of 700 rpm.

First two stitches are sewn at a low speed of 400 rpm.

Low speed sewing is not performed at the start of sewing.

The motor operates in reverse when the upper shaft stops, to return the needle 
bar to close to its highest position. *NOTE

Switch

 DANGER

12-2. DIP switches inside the control box

Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from
the wall outlet before opening the face plate of the control box. Touching areas where high volt-
ages are present can result in severe injury.

The functions can be changed as shown in the table
below by changing the positions of the DIP switches
q.
* All DIP switches are set to OFF at the time of ship-

ment.

NOTE:

When opening the cover, hold it securely so that it does
not fall down.

12. CHANGING FUNCTIONS USING THE DIP SWITCHES

*NOTE:

When the motor operates in reverse to raise the needle, the thread take-up will stop at a position which is lower than
its normal stopping position. As a result, the thread take-up will rise slightly at the sewing start, and this may result in
the thread pulling out under certain coditions.