background image

7

Electrical Installation

Electrical requirements
You can find the identification plate with the electrical 

specifications on the underside of the appliance. The 

junction box must be located within 3 feet of the cooktop 

connection. It should be easily accessible for service 

purposes.
Refer to data plate for more information. See “Data Plate” 

under “Service” for data plate location.

Power supply

Connect Electrical Supply

9

WARNING

Before installing, turn off at the service panel. Lock 

service panel to prevent power from being turned 

on accidentally.

The electrical power supply system should be a 1-phase, 

3-wire system with ground connection. Install suitable 

junction box (not furnished). An appropriately-sized, UL-

listed conduit connector must be used to correctly attach 

the conduit to the junction box.
The branch-circuit breakers ampacity, the wire sizes and 

the connections must conform to the requirements of the 

National Electrical Code or Canadian Electrical Code and 

all local codes and ordinances.
Attach flexible conduit to the junction box.
Metal conduit and leads are factory installed.

9

WARNING

To reduce the risk of electrical shock and fire, do 

not use a flexible power-supply cord with this 

appliance. Connect only to a 3 wire, 120/240-volt 

power supply; the neutral conductor is not required 

for the operation of the appliance. The potential at 

the power supply electrical connections shall be 

150-volts-to-ground or less.

Connect the cooktop lead wires to the junction box 

supply wires in proper phase: 
black (L1) to black
red (L2) to red
green or blank copper wire to ground

Check the Installation

9

WARNING

Before you turn on power supply, make sure all 

controls are in the OFF position.

Remove everything from the cooktop surface including 

stickers. Clean cooktop surface with cooktop cleaning 

cream.
Switch on the circuit breaker.
Verify that elements function properly.

Model

240 V AC, 60 Hz 

system: circuit 

breaker

208 V AC, 60 Hz 

system: circuit 

breaker

NET8068SUC 40 Amp

30 Amp

NET8068UC

40 Amp

30 Amp

NET8668SUC 50 Amp

40 Amp

NET8668UC

50 Amp

40 Amp

NETP068SUC 40 Amp

40 Amp

NETP668SUC 40 Amp

40 Amp

NEM5066UC 30 Amp

30 Amp

NEM5666UC 40 Amp

40 Amp