Bosch HII8055U Installation Instructions | Page 9

Bosch Induction Cooktops Installation Instructions - HII8055U.
Download
Page  of 66
4.3, 1573 votes
background image

 English 5

Cabinet Requirements
This unit is designed for installation near adjacent walls and 

projecting surfaces constructed of combustible materials. 

Prepare the countertop and cabinets.

Allow a minimum of 30" (76.2 cm) between cabinets 
where range is to be installed. No side clearance is 

required. Height is set by adjusting the range legs (see 

later section, “Complete the installation” on 

page 11).

Note: The slide-in range can also replace a 
freestanding 

range. In this case, verify that the opening is 

at least 30" (76.2 cm).

Install Ventilation
Bosch strongly recommends the installation of a ventilation 

hood above this range. For most kitchens, a certified hood 

rating of not less than 300 CFM is recommended. The 

range hood must be installed according to instructions 

furnished with the hood.

Required Clearance
These instructions were determined using standard 

American cabinets. Standard base cabinets measure 36" 

(91.4 cm) high x 25" (63.5 cm) deep. Cabinets over the 

cooking surface and cabinets adjacent to those over the 

cooking surface measure 13" (33 cm) deep from backwall. 

If nonstandard cabinets are used, care should be taken to 

alter dimensions accordingly.

From cooktop to materials above: 

There must be a minimum clearance of 30” (762 mm)

between the top of the cooking surface and the bottom

of an unprotected wood or metal cabinet.

Bosch recommends the minimum clearances shown in

the installation diagrams contained in this manual.

Clearances from non-combustible materials are not

certified by CSA. Clearances less than shown in the

installation diagrams must be approved by local codes

and/or by the local authority having jurisdiction.

From the cooking surface to side materials:

No clearance is required from unit walls to adjacent vertical 

combustible walls on rear, right or left.

9

WARNING
To eliminate the risk of burns or fire by reaching over 

heated surface units, cabinet storage space located 

above the surface units should be avoided. If 

cabinet storage is to be provided, the risk can be 

reduced by installing a hood that projects 

horizontally a minimum of 5" (12.7 cm) beyond the 

bottom of the cabinet.

0.610461s