Connecting the appliance
After installing the appliance, wait at least 8 hours until 

the appliance is switched on. During transportation 

the oil in the compressor may have flowed into 

the refrigeration system.

CAUTION: 

Always connect the water before the power.

Before switching on the appliance for the first time, clean 

the interior of the appliance (see chapter Cleaning 

the appliance).

Water connection
The water may be connected only by a competent 

plumber according to the local regulations of 

the appropriate water supply company.

WARNING: 

Connect the appliance to a drinking water line 

only!

Minimum pressure: 29 psi (2 bar)

Maximum pressure: 116 psi (8 bar)

Pressure over 116 psi (8 bar): install a pressure 

limiter between drinking water connection and hose 

set

A cold water connection is necessary for operating the 

automatic ice maker.
Install a separate shut-off valve in the cold water supply 

line.
The shut-off valve should not be located behind the 

appliance. It is recommended that you mount the shut-off 

valve directly next to the appliance or at another place 

which is easily accessible.

Electrical connection
WARNING: 

Risk of electric shock!
Connect the appliance to a grounded, 3-phase 

outlet only. Never remove the ground phase. Do 

not use any adapters.Do not use any extension 

leads.

WARNING: 

Risk of electric shock!
Incorrect connection of the appliance may result 

in death, fire or electric shock. Improper 

connection of the protective conductor may result 

in electric shock. If you are in doubt as to whether 

the appliance has been properly grounded, have it 

tested by a qualified electrician or Customer 

Service technician.

WARNING: 

Risk of electric shock!
If the length of the power cord is inadequate, 

never use multiple outlets or extension leads. 

Instead, please contact Customer Service for 

alternatives.

This appliance must be connected to a permanently 

installed outlet.
The outlet must be near the appliance and also freely 

accessible following installation of the appliance.
The appliance complies with protection class I. Connect 

it to a correctly installed outlet. Correct means: with a 

protective conductor, 110 V – 120 V/60 Hz alternating 

current. The outlet must be protected by a 10 A – 16 A  

fuse.
The appliance comes with a UL registered 3-wire power 

cord. The appliance requires a 3-pole outlet.
Please observe the following table with regard to this:

Check on the rating plate whether the indicated voltage 

and current type match the values of your power supply. 

The position of the rating plate can be found in the 

chapter entitled Customer Service.

WARNING: 

Never connect the appliance to electronic energy 

saver plugs.
Our appliances can be used with mains and sine-

controlled inverters. Mains-controlled inverters are 

used for photovoltaic systems which are 

connected directly to the national grid. Sine-

controlled inverters must be used for isolated 

applications (e.g. on ships or in mountain lodges) 

which are not connected directly to the national 

grid.

Appliance

Maximum simultaneous 

load

Fridge-freezer

6 A