2. Equipment and Software Validated  

The following equipment and software were used for the configuration provided: 

Hardware/Software Component  

Software Version 

Communication Manager (with G450 Media 
Gateway) 

 R015x.02.1.016.4/

 R016x.00.1.510.1 

Session Manager (S8800 Server) 

6.1.3.0.613006  

System Manager (S8800 Server) 

6.1.0 (6.1.0.0.7345-6.1.5.112)  

96XX SIP/H323  

2.6.6.102/S3.103S 

6408+ Digital Telephone  

N/A 

1120,1230,1120,1140 

4.3 

B179 Conference Phone 

2.2.3 & 2.2.4 

 

 

 

3. Configuration of the Avaya B179 SIP Conference Telephone  

Using the buttons on the B179 SIP Conference Phone, set the IP Address information for the phone 
to  be  either  a  static  IP  address  or  to  use  DHCP.  In  this  case  a  static  IP  Address  was  entered,  and 
VLAN 511 was used.  

 

On the Phone select  MENU then use the ▲and▼keys to  the SETTINGS menu, then Click 

OK (select  key).  In the  SETTINGS  menu (not shown) select  ADVANCED, and enter the required 
password. Navigate to the NETWORK menu, and then select IP. Set the IP Address to either DHCP 
or STATIC. A dark box next to an entry indicates it is selected. If static, click OK and step through 
the  prompts  to  enter  the  IP  Address,  Mask,  and  Gateway  for  the  endpoint,  clicking  OK  after  each 
entry.  At  the  end  the  NETWORK  menu  re-appears.  If  a  VLAN  is  to  be  used,  select  ETHERNET, 
followed by VLAN. Select ENABLE VLAN, enter the VLAN number to be used, followed by OK. 
When done continue to press C until you reach the main menu, which time phone will reboot. At this 
point the remaining configuration can be done via the web interface. 

 

 