Atwood Mobile Products Atwood Mobile Products Furnace 7920-II User's Manual
1
THIS INSTRUCTION MANUAL IS FOR USE BY AN AUTHORIZED SERVICE
TECHNICIAN TO INSTALL AN ATWOOD
- hydro flameTM FURNACE.
INSTALLER
: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER
: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
This furnace design has been certified by the American Gas
Association and Canadian Gas Association for installation in
recreation vehicles as a MSP Category III furnace. Follow this
installation instruction to insure safe operation of the furnace.
Failure to install furnace according to this installation instruction
nullifies the furnace warranty.
SAFETY ALERT SYMBOLS
Safety Symbols alerting you to potential personal safety hazards.
Obey all safety messages following these symbols.
WARNING
CAUTION
avoid possible
avoid possible
injury or death
injury and/or property damage
INDEX
FURNACE SPECIFICATIONS
..............................................................1
DIMENSIONS
..................................................................1
WEIGHT
........................................................................1
DUCTING CONFIGURATION
................................................................1
MINIMUM CLEARANCE TO FLOORBOARDS
, WALLS,
& SIMILAR COMBUSTIBLE BUILDING MATERIALS
..................................2
SAFETY INFORMATION
................................................................1-2
FURNACE INSTALLATION
..............................................................2-4
CUTOUTS
..................................................................................2
DUCTING
................................................................................2-3
Flexible Ducting
......................................................................2
Venting Chart
........................................................................3
OPTIONAL INSTALLATION
- DIRECTIONAL AIR BOX
....................................3
PROPANE GAS CONNECTION
............................................................3
ELECTRICAL CONNECTIONS
..............................................................3
Thermostat Installation
............................................................3
Door Installation
....................................................................3
SYSTEM CHECK TESTS
....................................................................4
PROPANE GAS PRESSURE
..............................................................4
FIGURES
1-8 (INCLUDING DC WIRING DIAGRAM) ..........................................4
REPLACEMENT PARTS LIST
& DRAWING
..............................................8
SPECIFICATIONS
(W.C. = Water Column)
MODEL
#
7912-II
7916-II
7920-II
8012-II
Input BTU/HR
12,000
16,000
18,000
12,000
Output Capacity BTU/HR
9,160
12,160
13,680
9,120
Duct Static Pressure -
.20" W.C.
.10" W.C.
.10" W.C.
N/A
12 Volt Amperage (AMPS)
3.4
3.4
3.4
1.8
Watts
40.8
40.8
40.8
21.6
Power Supply (Volt DC)
12
12
12
12
MINIMUM RETURN AIR
35 in
2
35 in
2
35 in
2
35 in
2
DIMENSIONS
WEIGHT
ALL MODEL
WIDTH
HEIGHT
DEPTH
Casing
8-3/8˝
11-3/8˝
20-5/8˝
FURNACE
23 lbs
Door
9-7/8˝
11-1/2˝
1-1/4˝
SHIPPING
25 lbs
MINIMUM CLEARANCE TO
FLOORBOARDS
, WALLS & SIMILAR COMBUSTIBLE BUILDING MATERIALS
MUST BE PROVIDED THE FULL LENGTH AND WIDTH OF UNIT
Top and Sides
0˝
TO CASING SPACERS
(SCREW HEADS)
Extension Box
0˝
Rear
0˝
Bottom
0˝
TO CASING SPACERS
(SCREW HEADS)
ENGLISH, FRANCAIS (et Canada)
•Installation
Effective 1/08
MPD 32072
hydro flameTM
7900-II / 8000-II
Series Furnace
Technical Installation Manual
9
ONE
side duct
BOTH
side ducts
FRONT
WARNING: If the information in this manual is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Evacuate all persons from vehicle.
• Shut off gas supply at gas container or source.
• Do not touch any electrical switch, or use any
phone or radio in vehicle.
• Do not start vehicle’s engine or electric generator.
• Contact nearest gas supplier or qualified Service
Technician for repairs.
• If you cannot reach a gas supplier or qualified
Service Technician, contact the nearest fire
department.
• Do not turn on gas supply until gas leak(s) has
been repaired.
— Installation and service must be performed by a
qualified Service Technician, Service Center or
gas supplier.
79/80 SERIES
79 SERIES
79 SERIES
80 SERIES ( 8012-II)
DUCTING CONFIGURATIONS
Related Manuals for Atwood Mobile Products Atwood Mobile Products Furnace 7920-II
-
Bryant Furnace PLUS 90X 353AAV User's Manual
22 pages
-
Bryant Furnace 310AAV Service Manual
45 pages
-
Bryant Furnace 915SA Product data
16 pages
-
Bryant Furnace 350MAV User's Manual
12 pages
-
Bryant Furnace PLUS 95S 355CAV Owner's Manual
14 pages
-
Carrier Furnace WEATHERMAKER 8000 58ZAV Instruction Manual
24 pages
-
Coleman Furnace DGAA User's Manual
14 pages
-
Goodman Mfg Furnace GMS90453BXA Parts list
11 pages
-
Rheem Furnace CRITERION II Installation Manual
8 pages
-
Trane Furnace XR 90 SERIES Owner's Manual
16 pages
-
Carrier Furnace 58GS User's Manual
12 pages
-
Carrier Furnace 58MCB User's Manual
12 pages
-
Rinnai Furnace ENERGYSAVER ES38 User's Manual
44 pages
-
Bryant Furnace Condensing s 398AAV User's Manual
12 pages
-
Thermo Products Furnace Thermo Pride Furnace OL6RA072D48(B/R) User's Manual
75 pages
-
Thermo Products Furnace OL5-85 User's Manual
32 pages
-
Thermo Products Furnace Thermo Pride Furnace MHA1-75N User's Manual
61 pages
-
Atwood Mobile Products Furnace HYDRO FLAME 8940 User's Manual
7 pages
-
Westinghouse Furnace FG7TC 95.1% AFUE Two-Stage Technical Literature
8 pages
-
Maytag Furnace PGC2TC PGC2TL | Maytag M1200 95.1% AFUE Two-Stage Fixed-Speed Gas Furnace Technical Literature
8 pages
-
Rinnai Furnace EX22C (RHFE-559FTA) Installation and Operation Manual
84 pages
-
York Furnace TM9Y Technical Guide
4 pages
-
York Furnace TM9E User's Manual
8 pages
-
GAMA Furnace Gas-Fired Furnace User's Information Manual
40 pages