noise, check pressure and adjust at the regulator if
necessary.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.

Igniter operation
Check that the igniter for each burner successfully
ignites the gas.
If an igniter fails to work, first remove the plug from
the electrical power outlet, and then check that all
the electrical connections are in place.
If satisfactory operation cannot be achieved, contact
place of purchase or their appointed agent for
service.

Low flame setting
Check the low flame setting for each hob burner to
ensure that the minimum flame will not be
extinguished by air draughts.
• Light the burner.
• Turn the control until it engages in the minimum

position.

• Ensure the flame is stable and will not be

extinguished by air draughts.

To adjust the minimum flame:
Follow the procedure described in the gas
conversion instruction.

DO NOT MODIFY THIS APPLIANCE IN ANY WAY,
OTHER THAN AS DESCRIBED IN THESE
INSTRUCTIONS.

PC 640 T X AUS
PC 640 N T X AUS

R

TC

S

A

! The product was tested in accordance with AS4551 standard

Gas Consumption 

Gas Connection

Natural Gas (1.0 kPa)

ULPG (2.75 kPa)

Auxiliary Burner

Semi Rapid Burners

Wok Burner

Total

Ø Injector (mm)

0.85

1.10

1.19 (x2)

GC (MJ/hr)

3.6

6.0 

13.5

30.9

Ø Injector (mm)

0.50

0.64

0.70 (x2)

GC (MJ/hr)

3.3

Rapid Burner

1.24

7.8

0.80

9.0

5.5

13.0

30.8

Gas Inlet fitting

1/2” BSP (male) thread

Location of gas inlet

40 mm from rear edge

40 mm fro