background image

INSTALLATION & 

DUCTING

pg 5

IMPORTANT Before handling the rangehood during installation, it is recommended that
you remove the filter to prevent damage.

Fig 1.2 illustrates the minimum height from the hob surface to the underside of the rangehood. 

Electric hob - 600mm

Gas hob - 650mm

NOTICE: IF THE INTRUCTIONS FOR THE GAS HOB
SPECIFY A GREATER DISTANCE, THIS HAS TO BE 
OBSERVED. ANY INSTALLATION ABOVE 750MM WILL 
COMPROMISE PERFORMANCE. 

483/71

0/859

520/75

0/900

300/50

0/650

150

10

520, 750 & 900 // UNDERMOUNT HOOD

*ARU52AX-L

*314mm for bevelled edge panel

*