For Technical information call 1-888-479-8324.  A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.

Recovery capacity based on actual performance tests.
Water Connections - 3/4” on all models.
External heat trap nipples are factory-installed on all models
All models are ENERGY STAR® qualified.
All models are certified from sea level to 10,100 ft. elevations
*Propane (LP) gas - 37,000 BTU input for 50-gallon models and 36,000 BTU for 40-gallon models
GCVL 50 not available for Propane

Residential Gas Water Heaters 

ReSiDeNTiAL GAS MODeLS - SeRieS 100

August 2013 

Page 2 of 2

www.hotwatercanada.ca  

                                                                                          CANRG45250

MODeL 

NUMbeR

SeRieS

FiRST  

HOUR 

RATiNG  

GALLONS

eNeRGY

FACTOR

(eF)

GALLON

CApACiTY

bTU

iNpUT

peR 

HOUR 

NATURAL

ReCOVeRY

90°F RiSe

GALLONS

peR HOUR

FOAM

THiCKNeSS

(iNCHeS)

DiMeNSiONS iN iNCHeS

DRAFT

HOOD

OUTLeT

AppROX.

SHippiNG

weiGHT

(LbS)

bC  

COMpLiANT

A

b

C

D

e

F

  TALL MODELS

GCF-40

100

67 

.67

40

40,000

42

2

64-1/4

58-1/4

20

13

8

51-3/4

3 or 4

152

GCF-50

100

81

.67

50

40,000

42

2

63-1/2

57-1/4

22

13

8

50-1/4

3 or 4

167

  SHORT MODEL

GCFL-40

100

67

.67

40

40,000

42

2

54

47-3/4

22

13

8

41

3 or 4

149

GCFL-50

100

81

.67

50

40,000

42

2

55-3/4

49-1/2

24

13

8

42-1/2

3 or 4

183

B

A

F

D

1/2" GAS

CONNECTION

T&P VALVE

COLD

CONNECTION

C

E

HOT

CONNECTION

ANODE ROD

Maximum Hydrostatic Working Pressure: 150 PSI.