APC Back UPS XS 1200 User's Manual

APC Battery Charger User's Manual - Back UPS XS 1200.
Download
Page  of 2
4.8, 1161 votes
background image

CONNECT TVSS

Back-UPS® RS/XS 1200

User’s Manual

1

®

CONTENTS

RJ-45

USB

RJ-11

RJ-11

2

3

CONNECT BATTERY CARTRIDGE

OPERATING ENVIRONMENT

3

4 CONNECT EQUIPMENT / POWER

Monitor

Printer or Scanner

FAX

External Disk or
CD / DVD Drive

Input: 120V~

12A, 60Hz

Circuit Breaker

Push to Reset

SURGE ONLY

BATTERYBACKUP

Computer

5 CHECK BUILDING WIRING

FAULT INDICATOR

Building

Wiring Fault

Wall

Outlet

Modem/

Phone/Fax

TVSS GND

Building Wiring

Fault Indicator

6

Phone Jack

Computer

Modem Port

CONNECT PHONE/MODEM/FAX

TVSS GND

Wall

Outlet

Wal

Outlet

Modem/

Phone/Fax

7 CONNECT 10/100 Base-T or VOIP

Network Jack

Computer

Network Port

8

To Computer USB

Port

CONNECT INTERFACE

Data Port

BR24BP Battery Pack

Computer

11 INSTALL SOFTWARE ON 

COMPUTER

There are four status indicators (lights) on the front

panel of the Back-UPS (On Line, On Battery, Overload,

and Replace Battery).

On Line (green) - is lit whenever utility power is

powering the Battery Backup outlets.

On Battery (yellow) - is lit whenever the battery of

the Back-UPS is powering equipment connected to the

Battery Backup Outlets.

Four Beeps Every 30 Seconds - this alarm is

sounded whenever the Back-UPS is running On

Battery. Consider saving work in progress.

Overload (red) - is lit whenever power demand has

exceeded the capacity of the Back-UPS.

Continuous Tone - this alarm is sounded

whenever the Battery Backup outlets are

overloaded.

Circuit Breaker - the circuit breaker button

located on the rear panel of the Back-UPS will

stick out if an overload condition forces the Back-

UPS to disconnect itself from utility power. If the

button sticks out, disconnect non-essential

equipment. Reset the circuit breaker by pushing

the button inward.

Replace Battery (red) - is lit whenever the battery is

near the end of its useful life, or if the battery is not con-

nected (see above). A battery that is near the end of its use-

ful life has insufficient run-time and should be replaced.

Chirps for 1 Minute Every 5 Hours - this

alarm is sounded whenever the battery has failed

the automatic diagnostic test.

Note: Allow the Back-UPS to charge for a full

eight (8) hours prior to use.
Press the front panel Power ON/OFF switch and

observe that the following events occur after

pressing and releasing the switch:

• The green On Line indicator flashes.

• The yellow On Battery indicator lights while 

a Self-Test is being performed.

• When Self-Test has successfully completed, 

only the green On Line indicator will be lit.

• If the internal battery cartridge is not 

connected (see Step 2 above), the green On 

Line indicator and red Replace Battery 

indicators will light. The Back-UPS will also 

emit a chirping sound.

Continuous Beeping - this alarm is sounded

whenever a low battery condition is reached.

Battery run-time is very low. Promptly save any

work in progress and exit all open applications.

Shutdown the operating system, computer and

the Back-UPS.

If Autoplay is not enabled on the computer, proceed

as follows:
1. On the computer desktop of the display, double-

click on My Computer.

2. Double-click on the CD-ROM drive icon and

follow the on-screen instructions.

If the rear panel Building Wiring Fault (red)

indicator is lit, a potential shock hazard exists

due to one of the following conditions:
   •  Open or high resistance ground
   •  Hot or neutral polarity reversed
   •  Overloaded neutral circuit
Improper building wiring should be

corrected by a qualified electrician. Do not

use the Back-UPS until the condition that

caused the fault is corrected.
Note
: Improper building wiring will not

prevent the Back-UPS from operating, but it

will limit its protection capability.

9 SWITCH ON THE BACK-UPS

10 ORIENTATION

12

GROUND

The Back-UPS features a transient
voltage surge-suppression (TVSS)

screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.

Wall

Outlet

Modem/

Phone/Fax

TVSS GND

From Data Line

TVSS

Follow the

on-screen

instructions.

On Line

On Battery

Overload

Replace Battery

w

 

w

 

w.apc.com

®

RJ-45

USB

10/100 Base-T

VOIP

STATUS INDICATORS AND ALARMS

For connection of APC’s optional

external 24-volt battery pack

(BR24BP) to the Back-UPS RS/XS 1500.

(Back-UPS RS models only)

CABLE

32 - 104oF (0 - 40oC)

✔ ✔

Back-UPS® RS/XS 1500

Related Manuals for APC Back UPS XS 1200